Motor library

Electric motor specifications

Search motor specifications from the same catalog used in GDriver. Compare pole pairs, magnet construction, sizes, power and sensors, with sources and qualifications for each configuration.

Take the next step in GDriver

Put the motor data in context.

Use GDriver’s motor catalog and guided setup with a compatible FarDriver controller. Review your hardware, inspect live values and save a backup before changing settings.

Tuning, tuning guides and backups are free. Optional paid features focus on ride intelligence.

A catalog entry does not establish controller compatibility or a safe tune. Keep a working manufacturer configuration. GDriver is independent and not affiliated with FarDriver.

See supported features and compatibility →

Saved catalog from 2026-10-05. Checking for updates…

299 motors shown
Axon

Pulsar Light Bee

Current page; 60 mm magnets; 11 kg

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
60 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
23 kW
Peak / maximum power
46 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 23 kW
  • peak: 46 kW

Speed ratings

  • Not published

Published specifications and qualifications

Axon

Pulsar Ultra Bee

Current page; 82 mm magnets; 13.7 kg

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
82 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
26 kW
Peak / maximum power
55 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 26 kW
  • peak: 55 kW

Speed ratings

  • Not published

Published specifications and qualifications

Bafang

M210

MM G2300.250.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
250 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 250 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 650 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M410

MM G333.250.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
250 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 250 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 800 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M430

M430; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 / 750 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 1,000 / 1,200 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M510

MM G522.250.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
250 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 250 W

Speed ratings

  • Not published

Construction inference and conditional AN guidance

A replacement motor core explicitly sold for the Bafang M510 shows rectangular magnets enclosed beneath iron bridges around the rotor perimeter. This supports an IPM inference for the named M510 family.

  • The replacement-part photograph is model-specific but does not establish the exact hardware revision in the 2027 workbook.
  • This visual review establishes likely magnet placement only; no pole count, thermal limit or controller compatibility is inferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

M510 replacement part .ROTOR-M510, EAN 8595640729968; the photographed rotor has magnets inside the iron perimeter. · End face shows separate magnet bars buried below the rotor iron surface.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 850 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M560

MM G5300.750.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

An owner disassembled a Bafang M560 and photographed its rotor end face, showing rectangular magnets enclosed by rotor iron. This supports an IPM inference for the named M560 family.

  • The photographed motor is a 2023 owner sample; the exact 2027 workbook revision has not been disassembled or matched by serial number.
  • The photographs do not establish sensor compatibility with FarDriver or justify changing a working factory tune.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Tomblarom documents disassembling his M560 in December 2023; original and quoted teardown photographs retain model context. · Rotor end face has magnet bars within the surrounding iron, supporting interior rather than surface placement. · Removed rotor shows a continuous laminated iron outer circumference.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 / 750 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 950 / 1,220 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M620

MM G510.1000.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

GreenBikeKit identifies both M620/G510 replacement rotor versions and photographs their laminated iron outer circumference. An original G510 owner teardown shows the rotor end face with magnet slots inside the iron perimeter. Together these support an IPM family inference.

  • The owner sample predates the 2027 workbook; exact revision identity is not confirmed.
  • GreenBikeKit identifies a 2023 pinion change from 9 to 15 teeth. Neither pinion tooth count is a motor pole count or a complete internal reduction ratio.
  • Only magnet architecture is inferred; numerical ratings and sensor compatibility are not transferred between revisions.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Seller identifies both M620/G510 rotor versions, unchanged dimensions, and the 2023 change to rotor pinion and matching third gear. · Both versions show laminated iron at the rotor circumference. · Sinhu identifies and disassembles a Bafang G510/M620 in May 2020. · Rotor end view corroborates internal magnet slots; limited image resolution keeps the conclusion inferential.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 1,000 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 1,360 / 1,440 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
Bafang

M820

MM G532.250.C; OEM Workbook 2027

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
250 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 250 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • rated Power Options: 250 WPublished rated options; not an explicit S1 continuous ratingSource 1
  • maximum Possible Power Options: 530 WWorkbook peak-locked parameters; reconfiguration depends on application and battery. No duration specified.Source 1
CYC Motor

Photon 2

Complete conversion kit

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Protection derating: 100 °C
Protection maximum: 120 °C
Specifications, conditions and sources

Power ratings

  • nominal: 750 WComplete kit output statement; not established as bare-motor shaft rating.
  • peak: 2 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.
  • peak: 2 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absent

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Likely surface magnets: the Photon Gen 2 exploded illustration shows separate curved segments at the rotor circumference, bounded by end plates, with no enclosing iron bridges depicted. CYC independently identifies this generation as an inrunner. The inference comes from the illustrated rotor geometry, not from the word inrunner.

  • The exploded illustration is hosted and labeled by Cycloboost; its original author and production-revision fidelity have not been independently established. It is an illustration, not a teardown photograph or magnet-labeled cross-section.
  • CYC’s own architecture article confirms the inrunner change but does not explicitly state surface or interior magnets. Magnet placement remains inferred, not manufacturer-confirmed.
  • This inference applies only to Photon Gen 2. It does not establish Photon Pro construction, pole pairs, reduction, sensor compatibility or a FarDriver-tested tune.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Photon Gen 2 listing embeds the exploded motor illustration with labeled rotor and stator. · The illustrated rotor has distinct curved outer segments between end plates; this supports, but does not certify, surface placement. · CYC identifies Photon Gen 2 as a new inrunner replacing the Gen 1 outrunner; the architecture label alone does not establish magnet placement.

FarDriver AN guidance

Published specifications and qualifications

  • Power: nominal: 750 WComplete kit output statement; not established as bare-motor shaft rating.Source 1
  • Power: peak: 2 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.Source 1
  • Drive type: midSource 1 · Source 2
  • rated Power Options: 250 / 750 WSource 1
  • Peak power: 2 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absentSource 1 · Source 2
  • Position sensor: inrunnerGen 2 changes from Gen 1 outrunner; this does not establish magnet embeddingSource 1
  • Protection derating: 100 °CPhoton Gen 2 only. Manufacturer manual explicitly states temperature-based power reduction begins at 100 C. Does not establish a configured setting on a particular unit or apply to Photon Gen 1, Photon Pro, or X1 Pro.Source 1
  • Protection maximum: 120 °CPhoton Gen 2 only. Published programmed maximum temperature is 120 C. The text does not specify a hard shutdown action, so this value is not labeled a confirmed shutdown.Source 1
  • Temperature rating: peak temperature: 150 °CPhoton Gen 2 only. Manufacturer says this temperature can be reached under extreme conditions. Duration and measurement location are not stated. It is not a continuous operating rating or a recommended controller target; the same manual gives a 120 C programmed ceiling.Source 1
CYC Motor

Photon Pro

Complete conversion kit

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
4 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • nominal: 3 kWComplete kit output statement; not established as bare-motor shaft rating.
  • peak: 4 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.
  • peak: 4 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absent

Speed ratings

  • Not published

Published specifications and qualifications

  • Power: nominal: 3 kWComplete kit output statement; not established as bare-motor shaft rating.Source 1
  • Power: peak: 4 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.Source 1
  • Drive type: midSource 1 · Source 2
  • rated Power Options: 3,000 WSource 1
  • Peak power: 4 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absentSource 1 · Source 2
CYC Motor

X1 Pro Gen 4

Complete conversion kit

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
5 kW
See source conditions below
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
not published
Fitted; type not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 5 kWComplete kit output statement; not established as bare-motor shaft rating.
  • peak lower bound: 6 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.
  • peak: 6 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absent

Speed ratings

  • Not published

Published specifications and qualifications

  • Power: continuous: 5 kWComplete kit output statement; not established as bare-motor shaft rating.Source 1
  • Power: peak lower bound: 6 kWComplete kit; X1 Pro states 6000W+; duration and measurement point unspecified.Source 1
  • Drive type: midSource 1 · Source 2
  • rated Power Options: 5,000 WSource 1
  • Peak power: 6 kWComplete conversion-system claim; bare-motor peak not independently isolated; duration absentSource 1 · Source 2
  • magnet Construction: surfaceExact X1 Pro Gen 4. Golden Motor, the kit seller, explicitly describes an SPM rotor with sleeve-retained magnets. The current manufacturer page establishes the matching Gen 4 identity. Dealer-published construction evidence, not a manufacturer certification or independent teardown; no Photon model inherits this classification.Source 1 · Source 2
  • Position sensor: HallManufacturer Gen 4 manual; rotor sensing, distinct from the external wheel speed sensor.Source 1
  • Temperature sensor: Fitted; type not publishedManufacturer manual confirms a fitted sensor but does not identify resistance, part number, conversion curve, or protection temperatures.Source 1
EBMX

XLB-60 CORE

CORE

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
41 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 41 kWair cooled

Speed ratings

  • Not published

Voltage, current and drivetrain

  • kv: 87 manufacturer-KVShaft reference not specified · No explicit RPM/V unit is printed; winding selection remains required for a range.

Published specifications and qualifications

  • magnet Construction: ipmExact XLB-60 CORE 87KV/64 mm model. Two exact-model dealer listings explicitly identify an IPM rotor; the official manufacturer page confirms the matching model/winding/stator identity. Dealer-written topology evidence, not a manufacturer certification or independently inspected rotor. No RACE or older 105KV topology/rating transfer.Source 1 · Source 2 · Source 3
  • maximum Speed: 12,000 rpmManufacturer maximum stable rotor RPM for CORE 87KV. Does not establish a continuous-duty power rating.Source 1 · Source 2
EBMX

XLB-60 RACE

RACE

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
24 kW / 140 s
See source conditions below
Peak / maximum power
50 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 50 kWair cooled
  • continuous: 24 kW / 140 sair cooled

Speed ratings

  • Not published

Construction inference and conditional AN guidance

EBMX expressly specifies IPM for its XLB-60 RACE Air Cooled SKU 4513. The current XLB-60 RACE retains the product line and 10-pole/12-slot dual-Y architecture, supporting a construction-family inference.

  • The current page specifies 95 KV and 50 kW peak; SKU 4513 specifies 105 KV and 42 kW. They are not treated as identical revisions.
  • IPM continuity is inferred; none of the earlier numerical limits is copied.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Manufacturer SKU 4513 specification explicitly says Rotor Type IPM; 105 KV and 10 poles/12 slots. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • kv: 95 manufacturer-KVShaft reference not specified · No explicit RPM/V unit is printed; winding selection remains required for a range.

Configuration notes

  • The family page specifies 95 KV and 50 kW peak; SKU 4513 specifies 105 KV and 42 kW. Same short name does not establish identical winding or revision. No V1/V2 labels invented.
EBMX

XLB-60 RACE Air Cooled

XLB-60 RACE · Air Cooled SKU 4513

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
65 mm stator stack length
65 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
42 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
13,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 42 kW1200 phase amps; 92 V

Speed ratings

  • maximum: 13,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • kv: 105 manufacturer-KVShaft reference not specified · No explicit RPM/V unit is printed; winding selection remains required for a range.
  • peak Current: 1,400 Aphase · Current amplitude convention not specified
  • continuous Current: 600 Aphase · Current amplitude convention not specified · 35 Nm; duration and cooling test conditions not specified for this current claim

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Temperature rating: maximum motor temperature: 180 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Stator stack length: 65 mmSource 1
  • Magnet length: 65 mmSource 1

Configuration notes

  • The family page specifies 95 KV and 50 kW peak; SKU 4513 specifies 105 KV and 42 kW. Same short name does not establish identical winding or revision. No V1/V2 labels invented.
EBMX

XTA-60

55 mm stator; NJDC 605 encoder

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
12,000 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

EBMX explicitly says XTA-60 uses its high-RPM rotor design. The corresponding EBMX XLB-60 RACE product describes the EBMX rotor design and expressly specifies IPM, supporting likely shared magnet architecture.

  • The manufacturer does not explicitly state XTA-60 is IPM or shares identical rotor parts with XLB-60 RACE.
  • 55 mm stator and 115 KV remain specific to XTA-60. Encoder type and dual-Y winding do not themselves establish IPM.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Manufacturer explicitly links XTA-60 to the EBMX high-RPM rotor design. · Manufacturer names EBMX rotor design and expressly identifies this RACE motor as IPM.

FarDriver AN guidance

EBMX

XUB-80

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
80 mm stator stack length
Extra gear reduction
Not published
Rated power
40 kW
Manufacturer-rated; duty not assumed
Continuous power
20.5 kW / 1,680 s
32 kW / 140 s
30 kW / 1,680 s
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
12,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 40 kW
  • continuous: 20.5 kW / 1,680 sair cooled
  • continuous: 32 kW / 140 sair cooled
  • burst: 52 kW / 10 sair cooled
  • continuous: 30 kW / 1,680 swater cooled

Speed ratings

  • manufacturer rated: 12,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • kv: 85–90 manufacturer-KVShaft reference not specified · No explicit RPM/V unit is printed; winding selection remains required for a range.

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Temperature rating: winding rating: 180 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Stator stack length: 80 mmSource 1

XUB-80 (Australian page; revision unresolved) specification reference

This record describes contradictory content on an additional XUB-80 source page, not a separately identified motor. Preserve its claims as scoped reference material under XUB-80 without assigning the table to V1 or V2 or applying its numbers as presets. The Australian listing specifies EBMX X-9000-only controller compatibility; it does not establish a supported FarDriver pairing.

  • Protection derating: 140 °C · UnconfirmedPrinted in XUB-80 table on page titled Version 2. Intro and table power disagree; exact hardware revision, sensor location and hysteresis unresolved. Do not promote to any production motor profile.Source 1
  • Protection shutdown: 160 °C · UnconfirmedPrinted in XUB-80 table on page titled Version 2. Intro and table power disagree; exact hardware revision, sensor location and hysteresis unresolved. Do not promote to any production motor profile.Source 1
  • Power: continuous: 40 kW · UnconfirmedV2 introduction; contradicts/does not reconcile with lower timed table results.Source 1
  • Power: peak: 50 kW · UnconfirmedV2 introduction and table agree on 50 kW.Source 1
  • Power: time limited: 15.5 kW for 1,680 seconds · UnconfirmedTable; air cooled.Source 1
  • Power: time limited: 28 kW for 140 seconds · UnconfirmedTable; air cooled; called continuous run for 2m20s.Source 1
  • Power: time limited: 18 kW for 1,680 seconds · UnconfirmedTable; water cooled.Source 1

Configuration notes

  • Australian page mixes V2 introduction and unversioned specification table. Do not assign the unversioned record to V1 or V2.
Electro & Company

ETM 2.0

SKU 400-0004; current manufacturer product page

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
5 kW
See source conditions below
Peak / maximum power
8 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 5 kWManufacturer rating; voltage, cooling and measurement basis unspecified.
  • peak: 8 kWManufacturer rating; peak duration unspecified.
  • burst: 11 kWSeparate E&C findings statement; test conditions and duration unspecified.

Speed ratings

  • Not published

Published specifications and qualifications

  • Magnet construction: IPMExplicit V-magnet IPM rotor statement.Source 1
  • Drive type: mid-driveCentral chassis replacement with chain sprocket for EBOX/Mototec; placement established by described installation.Source 1
  • Power: continuous: 5 kWManufacturer rating; voltage, cooling and measurement basis unspecified.Source 1
  • Power: peak: 8 kWManufacturer rating; peak duration unspecified.Source 1
  • Power: burst: 11 kWSeparate E&C findings statement; test conditions and duration unspecified.Source 1
EMRAX

188

2 source records · Resolver or Encoder

View configurations and sources
One published motor model. v1.6 and v1.7 identify datasheet revisions. Keep each document’s configuration-specific specifications; unchanged hardware is not inferred.
EMRAX

188

all v1.6 voltage and cooling configurations

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
37 kW
See source conditions below
Peak / maximum power
60 kW / 120 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
8,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 37 kWconfiguration and cooling dependent
  • peak: 60 kW / 120 sat 6500 RPM

Speed ratings

  • limiting: 8,000 RPMShaft reference not specified

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 100 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

188

standard HV/MV/LV configurations, page 2

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
23 kW
29 kW
33 kW
See source conditions below
Peak / maximum power
60 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
8,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 23 kWHV; AC; S1; page 2 cooling requirements
  • continuous: 29 kWHV; LC; S1; page 2 cooling requirements
  • continuous: 33 kWHV; CC; S1; page 2 cooling requirements
  • peak: 60 kW / 30 sHV; 6500 RPM; page 2 cooling/voltage requirements
  • continuous: 23 kWMV; AC; S1; page 2 cooling requirements
  • continuous: 29 kWMV; LC; S1; page 2 cooling requirements
  • continuous: 33 kWMV; CC; S1; page 2 cooling requirements
  • peak: 60 kW / 30 sMV; 6500 RPM; page 2 cooling/voltage requirements
  • continuous: 23 kWLV; AC; S1; page 2 cooling requirements
  • continuous: 29 kWLV; LC; S1; page 2 cooling requirements
  • continuous: 33 kWLV; CC; S1; page 2 cooling requirements
  • peak: 60 kW / 30 sLV; 6500 RPM; page 2 cooling/voltage requirements

Speed ratings

  • limiting: 8,000 RPMShaft reference not specified · Main-table standard HV/MV/LV configurations; voltage may impose a lower operating speed.

Voltage, current and drivetrain

  • kv: 17.73 RPM/Vmotor rotor · HV; no load
  • peak Current: 190 Aphase · rms · HV; page 2 conditions
  • continuous Current: 100 Aphase · rms · HV; LC
  • kv: 29.58 RPM/Vmotor rotor · MV; no load
  • peak Current: 310 Aphase · rms · MV; page 2 conditions
  • continuous Current: 160 Aphase · rms · MV; LC
  • kv: 72.82 RPM/Vmotor rotor · LV; no load
  • peak Current: 900 Aphase · rms · LV; page 2 conditions
  • continuous Current: 400 Aphase · rms · LV; LC

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

208

2 source records · Resolver or Encoder

View configurations and sources
One published motor model. v1.6 and v1.7 identify datasheet revisions. Keep each document’s configuration-specific specifications; unchanged hardware is not inferred.
EMRAX

208

all v1.6 voltage and cooling configurations

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
56 kW
See source conditions below
Peak / maximum power
86 kW / 120 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
7,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 56 kWconfiguration and cooling dependent
  • peak: 86 kW / 120 sat 6000 RPM

Speed ratings

  • limiting: 7,000 RPMShaft reference not specified

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 100 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

208

standard HV/MV/LV configurations, page 2

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
33 kW
47 kW
52 kW
See source conditions below
Peak / maximum power
86 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
7,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 33 kWHV; AC; S1; page 2 cooling requirements
  • continuous: 47 kWHV; LC; S1; page 2 cooling requirements
  • continuous: 52 kWHV; CC; S1; page 2 cooling requirements
  • peak: 86 kW / 30 sHV; 6000 RPM; page 2 cooling/voltage requirements
  • continuous: 33 kWMV; AC; S1; page 2 cooling requirements
  • continuous: 47 kWMV; LC; S1; page 2 cooling requirements
  • continuous: 52 kWMV; CC; S1; page 2 cooling requirements
  • peak: 86 kW / 30 sMV; 6000 RPM; page 2 cooling/voltage requirements
  • continuous: 33 kWLV; AC; S1; page 2 cooling requirements
  • continuous: 47 kWLV; LC; S1; page 2 cooling requirements
  • continuous: 52 kWLV; CC; S1; page 2 cooling requirements
  • peak: 86 kW / 30 sLV; 6000 RPM; page 2 cooling/voltage requirements

Speed ratings

  • limiting: 7,000 RPMShaft reference not specified · Main-table standard HV/MV/LV configurations; voltage may impose a lower operating speed.

Voltage, current and drivetrain

  • kv: 15.53 RPM/Vmotor rotor · HV; no load
  • peak Current: 240 Aphase · rms · HV; page 2 conditions
  • continuous Current: 140 Aphase · rms · HV; LC
  • kv: 25.02 RPM/Vmotor rotor · MV; no load
  • peak Current: 400 Aphase · rms · MV; page 2 conditions
  • continuous Current: 220 Aphase · rms · MV; LC
  • kv: 64.01 RPM/Vmotor rotor · LV; no load
  • peak Current: 1,000 Aphase · rms · LV; page 2 conditions
  • continuous Current: 560 Aphase · rms · LV; LC

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

228

2 source records · Resolver or Encoder

View configurations and sources
One published motor model. v1.6 and v1.7 identify datasheet revisions. Keep each document’s configuration-specific specifications; unchanged hardware is not inferred.
EMRAX

228

all v1.6 voltage and cooling configurations

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
75 kW
See source conditions below
Peak / maximum power
124 kW / 120 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,500 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 75 kWconfiguration and cooling dependent
  • peak: 124 kW / 120 sat 5500 RPM

Speed ratings

  • limiting: 6,500 RPMShaft reference not specified

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 100 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

228

standard HV/MV/LV configurations, page 2

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
48 kW
68 kW
75 kW
See source conditions below
Peak / maximum power
104 kW / 30 s · peak
124 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,500 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 48 kWHV; AC; S1; page 2 cooling requirements
  • continuous: 68 kWHV; LC; S1; page 2 cooling requirements
  • continuous: 75 kWHV; CC; S1; page 2 cooling requirements
  • peak: 104 kW / 30 sHV; 4500 RPM; page 2 cooling/voltage requirements
  • continuous: 48 kWMV; AC; S1; page 2 cooling requirements
  • continuous: 68 kWMV; LC; S1; page 2 cooling requirements
  • continuous: 75 kWMV; CC; S1; page 2 cooling requirements
  • peak: 124 kW / 30 sMV; 5500 RPM; page 2 cooling/voltage requirements
  • continuous: 48 kWLV; AC; S1; page 2 cooling requirements
  • continuous: 68 kWLV; LC; S1; page 2 cooling requirements
  • continuous: 75 kWLV; CC; S1; page 2 cooling requirements
  • peak: 124 kW / 30 sLV; 5500 RPM; page 2 cooling/voltage requirements

Speed ratings

  • limiting: 6,500 RPMShaft reference not specified · Main-table standard HV/MV/LV configurations; voltage may impose a lower operating speed.

Voltage, current and drivetrain

  • kv: 10.14 RPM/Vmotor rotor · HV; no load
  • peak Current: 235 Aphase · rms · HV; page 2 conditions
  • continuous Current: 120 Aphase · rms · HV; LC
  • kv: 15.53 RPM/Vmotor rotor · MV; no load
  • peak Current: 360 Aphase · rms · MV; page 2 conditions
  • continuous Current: 180 Aphase · rms · MV; LC
  • kv: 40.3 RPM/Vmotor rotor · LV; no load
  • peak Current: 920 Aphase · rms · LV; page 2 conditions
  • continuous Current: 470 Aphase · rms · LV; LC

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

268

all v1.6 voltage and cooling configurations

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
117 kW
See source conditions below
Peak / maximum power
210 kW / 60 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,500 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 117 kWconfiguration and cooling dependent
  • peak: 210 kW / 60 sat 4500 RPM

Speed ratings

  • limiting: 4,500 RPMShaft reference not specified

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2

Configuration notes

  • Document revision alone is not hardware, but the changed model designation 268-C cannot be discarded.
EMRAX

268-C

standard HV/MV/LV configurations, page 2

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
58 kW
82 kW
90 kW
64 kW
91 kW
101 kW
See source conditions below
Peak / maximum power
135 kW / 30 s · peak
210 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,500 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 58 kWHV; AC; S1; page 2 cooling requirements
  • continuous: 82 kWHV; LC; S1; page 2 cooling requirements
  • continuous: 90 kWHV; CC; S1; page 2 cooling requirements
  • peak: 135 kW / 30 sHV; 2400 RPM; page 2 cooling/voltage requirements
  • continuous: 64 kWMV; AC; S1; page 2 cooling requirements
  • continuous: 91 kWMV; LC; S1; page 2 cooling requirements
  • continuous: 101 kWMV; CC; S1; page 2 cooling requirements
  • peak: 210 kW / 30 sMV; 4250 RPM; page 2 cooling/voltage requirements
  • continuous: 64 kWLV; AC; S1; page 2 cooling requirements
  • continuous: 91 kWLV; LC; S1; page 2 cooling requirements
  • continuous: 101 kWLV; CC; S1; page 2 cooling requirements
  • peak: 210 kW / 30 sLV; 4250 RPM; page 2 cooling/voltage requirements

Speed ratings

  • limiting: 4,500 RPMShaft reference not specified · Main-table standard HV/MV/LV configurations; voltage may impose a lower operating speed.

Voltage, current and drivetrain

  • kv: 5.83 RPM/Vmotor rotor · HV; no load
  • peak Current: 320 Aphase · rms · HV; page 2 conditions
  • continuous Current: 130 Aphase · rms · HV; LC
  • kv: 8.68 RPM/Vmotor rotor · MV; no load
  • peak Current: 500 Aphase · rms · MV; page 2 conditions
  • continuous Current: 220 Aphase · rms · MV; LC
  • kv: 23.56 RPM/Vmotor rotor · LV; no load
  • peak Current: 1,300 Aphase · rms · LV; page 2 conditions
  • continuous Current: 550 Aphase · rms · LV; LC

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2

Configuration notes

  • Document revision alone is not hardware, but the changed model designation 268-C cannot be discarded.
EMRAX

348

2 source records · Resolver or Encoder

View configurations and sources
One published motor model. v1.6 and v1.7 identify datasheet revisions. Keep each document’s configuration-specific specifications; unchanged hardware is not inferred.
EMRAX

348

all v1.6 voltage and cooling configurations

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
145 kW
See source conditions below
Peak / maximum power
340 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
3,250 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 145 kWconfiguration and cooling dependent
  • peak: 340 kW / 30 sat 3250 RPM

Speed ratings

  • limiting: 3,250 RPMShaft reference not specified

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EMRAX

348

standard HV/MV/LV configurations, page 2

Pole pairs
10
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
54 kW
77 kW
85 kW
84 kW
120 kW
132 kW
112 kW
160 kW
176 kW
See source conditions below
Peak / maximum power
112 kW / 30 s · peak
174 kW / 30 s · peak
340 kW / 30 s · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,500 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY81/210
Position sensor options
Resolver
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 54 kWHV; AC; S1; page 2 cooling requirements
  • continuous: 77 kWHV; LC; S1; page 2 cooling requirements
  • continuous: 85 kWHV; CC; S1; page 2 cooling requirements
  • peak: 112 kW / 30 sHV; 1340 RPM; page 2 cooling/voltage requirements
  • continuous: 84 kWMV; AC; S1; page 2 cooling requirements
  • continuous: 120 kWMV; LC; S1; page 2 cooling requirements
  • continuous: 132 kWMV; CC; S1; page 2 cooling requirements
  • peak: 174 kW / 30 sMV; 2080 RPM; page 2 cooling/voltage requirements
  • continuous: 112 kWLV; AC; S1; page 2 cooling requirements
  • continuous: 160 kWLV; LC; S1; page 2 cooling requirements
  • continuous: 176 kWLV; CC; S1; page 2 cooling requirements
  • peak: 340 kW / 30 sLV; 4000 RPM; page 2 cooling/voltage requirements

Speed ratings

  • limiting: 4,500 RPMShaft reference not specified · Main-table standard HV/MV/LV configurations; voltage may impose a lower operating speed.

Voltage, current and drivetrain

  • kv: 3.18 RPM/Vmotor rotor · HV; no load
  • peak Current: 375 Aphase · rms · HV; page 2 conditions
  • continuous Current: 150 Aphase · rms · HV; LC
  • kv: 4.92 RPM/Vmotor rotor · MV; no load
  • peak Current: 570 Aphase · rms · MV; page 2 conditions
  • continuous Current: 230 Aphase · rms · MV; LC
  • kv: 13.18 RPM/Vmotor rotor · LV; no load
  • peak Current: 1,500 Aphase · rms · LV; page 2 conditions
  • continuous Current: 550 Aphase · rms · LV; LC

Published specifications and qualifications

  • Temperature rating: maximum sensor temperature: 100 °C (integrated temperature sensor)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum rotor surface temperature: 80 °C (rotor surface)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: absolute component temperature limit: 120 °C (integrated parts)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceStandard EMRAX 188/208/228/268/348 architecture: manufacturer describes magnets fixed on the rotor back iron. The current manual identifies the same model range and axial-flux outrunner architecture. Datasheet revision power and thermal ratings remain separate.Source 1 · Source 2
EnerTrac

MHM602

2-turn winding in manufacturer product sheet

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
10 kW
See source conditions below
Peak / maximum power
30 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Protection behavior: Thermally protected when using recommended Kelly controller; numeric thresholds not stated.
Specifications, conditions and sources

Power ratings

  • continuous: 10 kW25°C ambient; exact manufacturer product sheet for MHM602 and MHM603.
  • peak: 30 kWUp to 30 kW; duration unspecified. Manufacturer product sheet.
  • continuous: 10 kWAt 25 C ambient, per product specification
  • peak: 30 kWUp to 30 kW; duration unspecified

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Power: continuous: 10 kW25°C ambient; exact manufacturer product sheet for MHM602 and MHM603.Source 1
  • Power: peak: 30 kWUp to 30 kW; duration unspecified. Manufacturer product sheet.Source 1
  • Protection behavior: Thermally protected when using recommended Kelly controller; numeric thresholds not stated.Source 1
  • Drive type: hubSource 1
  • Continuous power: 10 kWAt 25 C ambient, per product specificationSource 1
  • Peak power: 30 kWUp to 30 kW; duration unspecifiedSource 1
EnerTrac

MHM603

3-turn winding in manufacturer product sheet

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
10 kW
20 kW
See source conditions below
Peak / maximum power
30 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Protection behavior: Thermally protected when using recommended Kelly controller; numeric thresholds not stated.
Specifications, conditions and sources

Power ratings

  • continuous: 10 kW25°C ambient; exact manufacturer product sheet for MHM602 and MHM603.
  • peak: 30 kWUp to 30 kW; duration unspecified. Manufacturer product sheet.
  • continuous: 20 kWMHM603 liquid cooling option only, explicitly stated under its heading. Coolant flow and inlet temperature not specified; not inherited by MHM602 or dual-motor system.
  • continuous: 10 kWAt 25 C ambient, per product specification
  • peak: 30 kWUp to 30 kW; duration unspecified

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Power: continuous: 10 kW25°C ambient; exact manufacturer product sheet for MHM602 and MHM603.Source 1
  • Power: peak: 30 kWUp to 30 kW; duration unspecified. Manufacturer product sheet.Source 1
  • Protection behavior: Thermally protected when using recommended Kelly controller; numeric thresholds not stated.Source 1
  • Power: continuous: 20 kWMHM603 liquid cooling option only, explicitly stated under its heading. Coolant flow and inlet temperature not specified; not inherited by MHM602 or dual-motor system.Source 1
  • Drive type: hubSource 1
  • Continuous power: 10 kWAt 25 C ambient, per product specificationSource 1
  • Peak power: 30 kWUp to 30 kW; duration unspecifiedSource 1
Golden Motor

BLDC-108

Current product-family specification; separate from archived dynamometer configurations

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
3 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 3 kWExplicit peak wording; duration and test conditions absent

Speed ratings

  • Not published

Published specifications and qualifications

  • voltage Options: 48 VSource 1
  • rated Power Range: 1,500 / 1,500 WSource 1
  • Peak power: 3 kWExplicit peak wording; duration and test conditions absentSource 1
  • Pole pairs: 5Source 1

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM-20KW

Current product-family specification; separate from archived dynamometer configurations

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
50 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 50 kWExplicit peak wording; duration and test conditions absent

Speed ratings

  • Not published

Published specifications and qualifications

  • voltage Options: 72 / 96 / 120 VSource 1
  • rated Power Range: 20,000 / 25,000 WSource 1
  • Peak power: 50 kWExplicit peak wording; duration and test conditions absentSource 1

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM-20KW

72 V; factory test 2015-07-22

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
20 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,600 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 20 kW

Speed ratings

  • Not published

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM3000

48 V; factory test 2014-12-31

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
4,000 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

The manufacturer HPM3000B fan-cooled IGES has separate magnet sectors and a back-iron disc consistent with surface magnets. The same factory HPM3000B section links the archived HPM3000 48 V and 72 V test reports, making a construction-family inference reasonable.

  • The CAD is dated January 2015; it does not certify every present or archived physical revision.
  • Ten magnet instances in CAD conflict with the four pole pairs measured on a 2019 academic specimen; neither pole count is transferred.
  • Construction only; no winding, pole-pair, power, temperature or cooling-option equivalence is asserted.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Manufacturer CAD: internal magnet sectors (3KW 磁钢) separate from the back-iron disc (导磁盘); previously rendered and inspected. · Manufacturer section names HPM3000B and links fan-cooled CAD plus both HPM3000 factory test reports. · 2022 UFF study Annex A labels the 2014-12-31 48 V test HPM3000B; separate measured specimen has four pole pairs. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM3000

72 V; factory test 2014-12-31

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,800 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

The manufacturer HPM3000B fan-cooled IGES has separate magnet sectors and a back-iron disc consistent with surface magnets. The same factory HPM3000B section links the archived HPM3000 48 V and 72 V test reports, making a construction-family inference reasonable.

  • The CAD is dated January 2015; it does not certify every present or archived physical revision.
  • Ten magnet instances in CAD conflict with the four pole pairs measured on a 2019 academic specimen; neither pole count is transferred.
  • Construction only; no winding, pole-pair, power, temperature or cooling-option equivalence is asserted.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Manufacturer CAD: internal magnet sectors (3KW 磁钢) separate from the back-iron disc (导磁盘); previously rendered and inspected. · Manufacturer section names HPM3000B and links fan-cooled CAD plus both HPM3000 factory test reports. · 2022 UFF study Annex A labels the 2014-12-31 48 V test HPM3000B; separate measured specimen has four pole pairs. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM3000B

Current product-family specification; separate from archived dynamometer configurations

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 6 kWExplicit peak wording; duration and test conditions absent

Speed ratings

  • Not published

Construction inference and conditional AN guidance

The manufacturer HPM3000B fan-cooled IGES has separate magnet sectors and a back-iron disc consistent with surface magnets. The same factory HPM3000B section links the archived HPM3000 48 V and 72 V test reports, making a construction-family inference reasonable.

  • The CAD is dated January 2015; it does not certify every present or archived physical revision.
  • Ten magnet instances in CAD conflict with the four pole pairs measured on a 2019 academic specimen; neither pole count is transferred.
  • Construction only; no winding, pole-pair, power, temperature or cooling-option equivalence is asserted.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Manufacturer CAD: internal magnet sectors (3KW 磁钢) separate from the back-iron disc (导磁盘); previously rendered and inspected. · Manufacturer section names HPM3000B and links fan-cooled CAD plus both HPM3000 factory test reports. · 2022 UFF study Annex A labels the 2014-12-31 48 V test HPM3000B; separate measured specimen has four pole pairs. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Published specifications and qualifications

  • voltage Options: 48 / 72 VSource 1
  • rated Power Range: 2,000 / 3,000 WSource 1
  • Peak power: 6 kWExplicit peak wording; duration and test conditions absentSource 1

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM48-10000

48 V; factory test G20130522003

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
10 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,500 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW

Speed ratings

  • Not published

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM48-5000

48 V; factory test G20130514008

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,500 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Likely surface magnets for this archived HPM5000 configuration: an original 2009 HPM5000B teardown clearly shows magnets attached to an axial rotor disc. Golden Motor places the archived 48/72/96 V tests in that named product family. This supports a moderate historical-family inference, not exact test-specimen confirmation.

  • The teardown is a 48 V motor from 2009, not the exact motor tested in 2013. Other voltage windings are a family inference.
  • A later firsthand discussion documents a different HPM5000 internal design. The revision transition date is unknown, so construction of the exact archived specimen remains unverified.
  • No pole count, temperature, power, cooling-option equivalence, or current-production construction is transferred from the teardown. Confirm the fitted rotor before treating AN 0 as applicable.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Original owner gestalt dismantled an HPM5000B in November 2009; photographs document the actual motor. · The same owner identifies the motor as rated 48 V in reply 16 and supplies close-up rotor photographs in reply 17. · Personally inspected photograph shows separate magnet tiles attached to the face of the axial rotor disc and facing the winding/stator air gap. · The HPM5000B family section links the 48 V, 72 V and 96 V factory test reports used by the three archived catalog entries. The page itself does not specify magnet placement. · 2022 firsthand discussion and a different internal photograph establish that multiple HPM5000 versions exist. Their transition date and correspondence to the archived tests are not established. · Manufacturer dynamometer report identifying this archived voltage/configuration; no rotor-construction statement.

FarDriver AN guidance

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM72-10000

72 V; factory test G20130522004

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
10 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,500 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW

Speed ratings

  • Not published

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM72-5000

72 V; factory test G20130516001

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,500 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Likely surface magnets for this archived HPM5000 configuration: an original 2009 HPM5000B teardown clearly shows magnets attached to an axial rotor disc. Golden Motor places the archived 48/72/96 V tests in that named product family. This supports a moderate historical-family inference, not exact test-specimen confirmation.

  • The teardown is a 48 V motor from 2009, not the exact motor tested in 2013. Other voltage windings are a family inference.
  • A later firsthand discussion documents a different HPM5000 internal design. The revision transition date is unknown, so construction of the exact archived specimen remains unverified.
  • No pole count, temperature, power, cooling-option equivalence, or current-production construction is transferred from the teardown. Confirm the fitted rotor before treating AN 0 as applicable.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Original owner gestalt dismantled an HPM5000B in November 2009; photographs document the actual motor. · The same owner identifies the motor as rated 48 V in reply 16 and supplies close-up rotor photographs in reply 17. · Personally inspected photograph shows separate magnet tiles attached to the face of the axial rotor disc and facing the winding/stator air gap. · The HPM5000B family section links the 48 V, 72 V and 96 V factory test reports used by the three archived catalog entries. The page itself does not specify magnet placement. · 2022 firsthand discussion and a different internal photograph establish that multiple HPM5000 versions exist. Their transition date and correspondence to the archived tests are not established. · Manufacturer dynamometer report identifying this archived voltage/configuration; no rotor-construction statement.

FarDriver AN guidance

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM96-10000

96 V; factory test G20130722001

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
10 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,700 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW

Speed ratings

  • Not published

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HPM96-5000

96 V; factory test G20130516004

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,700 RPM
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Likely surface magnets for this archived HPM5000 configuration: an original 2009 HPM5000B teardown clearly shows magnets attached to an axial rotor disc. Golden Motor places the archived 48/72/96 V tests in that named product family. This supports a moderate historical-family inference, not exact test-specimen confirmation.

  • The teardown is a 48 V motor from 2009, not the exact motor tested in 2013. Other voltage windings are a family inference.
  • A later firsthand discussion documents a different HPM5000 internal design. The revision transition date is unknown, so construction of the exact archived specimen remains unverified.
  • No pole count, temperature, power, cooling-option equivalence, or current-production construction is transferred from the teardown. Confirm the fitted rotor before treating AN 0 as applicable.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Original owner gestalt dismantled an HPM5000B in November 2009; photographs document the actual motor. · The same owner identifies the motor as rated 48 V in reply 16 and supplies close-up rotor photographs in reply 17. · Personally inspected photograph shows separate magnet tiles attached to the face of the axial rotor disc and facing the winding/stator air gap. · The HPM5000B family section links the 48 V, 72 V and 96 V factory test reports used by the three archived catalog entries. The page itself does not specify magnet placement. · 2022 firsthand discussion and a different internal photograph establish that multiple HPM5000 versions exist. Their transition date and correspondence to the archived tests are not established. · Manufacturer dynamometer report identifying this archived voltage/configuration; no rotor-construction statement.

FarDriver AN guidance

Configuration notes

  • HPM3000 and current HPM3000B may share family history, but the B suffix and old factory-test windings require exact mapping. A dynamometer record is a tested configuration, not an extra motor generation.
Golden Motor

HTM07K

72 V magnetic encoder; natural cooling

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
1,950 RPM · shaft reference unspecified
Maximum / peak RPM
3,600 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • manufacturer rated: 1,950 RPMShaft reference not specified
  • maximum: 3,600 RPMShaft reference not specified

Construction inference and conditional AN guidance

Likely surface magnets: Golden Motor’s current HyperTorque listing explicitly describes surface magnets on twin rotor discs and links the manufacturer’s HTM07KW/HTM11KW sheet. The catalog’s earlier HTM07K/HTM11K sheet retains the same paired models, voltage, currents, phase resistance and pole pairs, supporting a family inference across the differing specifications.

  • The earlier catalog sheet and the currently linked sheet differ in power, speed, torque, weight and ingress ratings. Exact revision equivalence is not established.
  • The explicit construction statement is from Golden Motor’s sales site; the earlier factory sheet does not describe magnet placement. The downloaded HTM11KW STEP omits the active rotor and magnets and is not construction evidence.
  • No current power, speed, temperature-sensor, duty or protection rating is copied into the earlier configuration. AN 0 is conditional starting guidance, not a factory tune or a confirmation of encoder compatibility.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Current HyperTorque listing explicitly identifies a single stator, two disc rotors and surface-mounted permanent magnets; directly links the manufacturer HTM07KW/HTM11KW specification sheet. · Current two-page sheet identifies HTM07KW/HTM11KW: 72 V, 92/170 A rated current, 400/800 A maximum phase current, 18.6/6.7 mOhm phase resistance and five pole pairs. These match the earlier paired sheet; several performance ratings differ. · Earlier three-page sheet is the catalog source for HTM07K/HTM11K. It publishes 6/11 kW, 3600/4000 RPM maximum, 14.6/17.4 kg and IP66, differing from the current sheet; these earlier configuration values remain unchanged.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 72 Vmotor · The table labels Voltage, not Rated Voltage.
  • rated Current: 92 Aunspecified · Current amplitude convention not specified · The table does not label the rated current as battery/line or phase.
  • maximum Current: 400 Aphase · Current amplitude convention not specified · Maximum current duration 30 seconds
Golden Motor

HTM11K

72 V magnetic encoder; natural cooling

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
11 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
2,500 RPM · shaft reference unspecified
Maximum / peak RPM
4,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 11 kW

Speed ratings

  • manufacturer rated: 2,500 RPMShaft reference not specified
  • maximum: 4,000 RPMShaft reference not specified

Construction inference and conditional AN guidance

Likely surface magnets: Golden Motor’s current HyperTorque listing explicitly describes surface magnets on twin rotor discs and links the manufacturer’s HTM07KW/HTM11KW sheet. The catalog’s earlier HTM07K/HTM11K sheet retains the same paired models, voltage, currents, phase resistance and pole pairs, supporting a family inference across the differing specifications.

  • The earlier catalog sheet and the currently linked sheet differ in power, speed, torque, weight and ingress ratings. Exact revision equivalence is not established.
  • The explicit construction statement is from Golden Motor’s sales site; the earlier factory sheet does not describe magnet placement. The downloaded HTM11KW STEP omits the active rotor and magnets and is not construction evidence.
  • No current power, speed, temperature-sensor, duty or protection rating is copied into the earlier configuration. AN 0 is conditional starting guidance, not a factory tune or a confirmation of encoder compatibility.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Current HyperTorque listing explicitly identifies a single stator, two disc rotors and surface-mounted permanent magnets; directly links the manufacturer HTM07KW/HTM11KW specification sheet. · Current two-page sheet identifies HTM07KW/HTM11KW: 72 V, 92/170 A rated current, 400/800 A maximum phase current, 18.6/6.7 mOhm phase resistance and five pole pairs. These match the earlier paired sheet; several performance ratings differ. · Earlier three-page sheet is the catalog source for HTM07K/HTM11K. It publishes 6/11 kW, 3600/4000 RPM maximum, 14.6/17.4 kg and IP66, differing from the current sheet; these earlier configuration values remain unchanged.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 72 Vmotor · The table labels Voltage, not Rated Voltage.
  • rated Current: 170 Aunspecified · Current amplitude convention not specified · The table does not label the rated current as battery/line or phase.
  • maximum Current: 800 Aphase · Current amplitude convention not specified · Maximum current duration 30 seconds
Grin Technologies

All-Axle v3

3 configurations · Hall

View configurations and sources
Manufacturer identifies V3 Front as one mechanical model offered in several winding speeds. V3 Rear and Max45 are different mechanical models.
Grin Technologies

All-Axle v3

All-Axle · Front fast black 5T SKU M-AA2705FB

Pole pairs
23
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
27 mm stator stack length
Extra gear reduction
Not published
Rated power
250 W
500 W
740 W · Conflicting sources — do not use
750 W · Conflicting sources — do not use
See source conditions below
Continuous power
250 W
340 W
560 W
785 W
900 W
1.275 kW
1.25 kW
1.84 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 500 W / 300 s100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 575 W / 300 s100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.04 kW / 300 s200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.235 kW / 300 s200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.59 kW / 300 s300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.83 kW / 300 s300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.11 kW / 300 s400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.42 kW / 300 s400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • Manufacturer rated: 250 WEU/Eurasia; 100 RPM hill climb; manual section 5.4
  • Manufacturer rated: 500 WCanada; just under 200 RPM hill climb; manual section 5.4
  • Manufacturer rated: 740 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree
  • Manufacturer rated: 750 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Temperature rating: recommended core upper temperature range: 110–120 °C (core)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubSource 1
  • Power: continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 500 W for 300 seconds100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 575 W for 300 seconds100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.04 kW for 300 seconds200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.235 kW for 300 seconds200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.59 kW for 300 seconds300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.83 kW for 300 seconds300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.11 kW for 300 seconds400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.42 kW for 300 seconds400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Stator stack length: 27 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

All-Axle v3

All-Axle · Front slow black 8T SKU M-AA2708FB

Pole pairs
23
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
27 mm stator stack length
Extra gear reduction
Not published
Rated power
250 W
500 W
740 W · Conflicting sources — do not use
750 W · Conflicting sources — do not use
See source conditions below
Continuous power
250 W
340 W
560 W
785 W
900 W
1.275 kW
1.25 kW
1.84 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 500 W / 300 s100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 575 W / 300 s100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.04 kW / 300 s200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.235 kW / 300 s200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.59 kW / 300 s300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.83 kW / 300 s300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.11 kW / 300 s400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.42 kW / 300 s400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • Manufacturer rated: 250 WEU/Eurasia; 100 RPM hill climb; manual section 5.4
  • Manufacturer rated: 500 WCanada; just under 200 RPM hill climb; manual section 5.4
  • Manufacturer rated: 740 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree
  • Manufacturer rated: 750 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Temperature rating: recommended core upper temperature range: 110–120 °C (core)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubSource 1
  • Power: continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 500 W for 300 seconds100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 575 W for 300 seconds100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.04 kW for 300 seconds200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.235 kW for 300 seconds200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.59 kW for 300 seconds300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.83 kW for 300 seconds300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.11 kW for 300 seconds400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.42 kW for 300 seconds400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Stator stack length: 27 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

All-Axle v3

All-Axle · Front standard black 6T SKU M-AA2706FB

Pole pairs
23
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
27 mm stator stack length
Extra gear reduction
Not published
Rated power
250 W
500 W
740 W · Conflicting sources — do not use
750 W · Conflicting sources — do not use
See source conditions below
Continuous power
250 W
340 W
560 W
785 W
900 W
1.275 kW
1.25 kW
1.84 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 500 W / 300 s100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 575 W / 300 s100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.04 kW / 300 s200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.235 kW / 300 s200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.59 kW / 300 s300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.83 kW / 300 s300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.11 kW / 300 s400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.42 kW / 300 s400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • Manufacturer rated: 250 WEU/Eurasia; 100 RPM hill climb; manual section 5.4
  • Manufacturer rated: 500 WCanada; just under 200 RPM hill climb; manual section 5.4
  • Manufacturer rated: 740 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree
  • Manufacturer rated: 750 W · Conflicting sources — do not useUSA; approximately 250 RPM; section 5.4 and specification table disagree

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Temperature rating: recommended core upper temperature range: 110–120 °C (core)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubSource 1
  • Power: continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 500 W for 300 seconds100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 575 W for 300 seconds100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.04 kW for 300 seconds200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.235 kW for 300 seconds200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.59 kW for 300 seconds300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.83 kW for 300 seconds300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.11 kW for 300 seconds400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.42 kW for 300 seconds400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Stator stack length: 27 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

All-Axle v3

All-Axle · Rear standard 6T XDR SKU M-AA2706R_TXD

Pole pairs
23
Physical rotor unless stated
Magnet construction
Surface magnets
Confirmed from rotor images
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Hub
Magnet / stator size
27 mm stator stack length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
250 W
340 W
560 W
785 W
900 W
1.275 kW
1.25 kW
1.84 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 500 W / 300 s100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 575 W / 300 s100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.04 kW / 300 s200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.235 kW / 300 s200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.59 kW / 300 s300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 1.83 kW / 300 s300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.11 kW / 300 s400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.
  • five minute: 2.42 kW / 300 s400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.

Speed ratings

  • Not published

Published specifications and qualifications

  • Temperature rating: recommended core upper temperature range: 110–120 °C (core)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubSource 1
  • Power: continuous: 250 W100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 500 W for 300 seconds100 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 340 W100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 575 W for 300 seconds100 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 560 W200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.04 kW for 300 seconds200 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 785 W200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.235 kW for 300 seconds200 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 900 W300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.59 kW for 300 seconds300 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.275 kW300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 1.83 kW for 300 seconds300 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.25 kW400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.11 kW for 300 seconds400 wheel rpm; dry; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: continuous: 1.84 kW400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Power: five minute: 2.42 kW for 300 seconds400 wheel rpm; with Statorade; 110°C core limit; 20°C ambient; airflow corresponding to 26-inch wheel. Manual table 3.Source 1
  • Magnet construction: SPMV3 rear All-Axle rotor construction. Manufacturer rear-motor manual explicitly points to the video. Surface mounting is visually interpreted from the exposed rotor, not a quoted SPM label. Winding and freehub options do not change the rotor shown by this common V3 rear service procedure.Source 1 · Source 2 · Source 3
  • Stator stack length: 27 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

Bafang G60

Grin 170–180 mm dropout configuration; OLD 170 mm

Pole pairs
10
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
5:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 5 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
Grin Technologies

Bafang G60_190

Grin 180–190 mm dropout configuration; OLD approximately 188 mm with inside washers

Pole pairs
10
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
5:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 5 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
Grin Technologies

Bafang_WB

Grin 16-inch wheelbarrow motor; M16×1.5 axle; Higo Z910

Pole pairs
8
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
29.9:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B3450
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 29.9 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubWheel-hub placement established by visual review of the exact original engineering drawing, including fixed axle and wheel/rim integration. This establishes placement only; magnet construction remains unconfirmed.Source 1
Grin Technologies

G310 3/8×26 TPI

G310 · Grin MG310_xxx; OLD 139 mm; 3/8×26 TPI axle; 2640 g

Pole pairs
8
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
11:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10k NTC B3400 · Conflicting sources — do not use
10K NTC B~3450 with 10K pullup · Conflicting sources — do not use
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Voltage, current and drivetrain

  • internal Reduction: 11 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • magnet Construction: surfaceG310/G311 rotor construction, including the 2021 stronger-adhesive update. Grin describes magnets bonded onto the rotor and lifting toward the stator if the adhesive fails.Source 1

Configuration notes

  • Rev 0 lists 138 mm OLD, M10×1 axle, 2550 g; rev 1 lists 139 mm OLD, 3/8×26 TPI axle, 2640 g. These are materially different published mechanical configurations even though the short model name repeats.
Grin Technologies

G310 M10×1

G310 · Grin MG310_xxx; OLD 138 mm; M10×1 axle; 2550 g

Pole pairs
8
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
11:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Voltage, current and drivetrain

  • internal Reduction: 11 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • magnet Construction: surfaceG310/G311 rotor construction, including the 2021 stronger-adhesive update. Grin describes magnets bonded onto the rotor and lifting toward the stator if the adhesive fails.Source 1

Configuration notes

  • Rev 0 lists 138 mm OLD, M10×1 axle, 2550 g; rev 1 lists 139 mm OLD, 3/8×26 TPI axle, 2640 g. These are materially different published mechanical configurations even though the short model name repeats.
Grin Technologies

G311

Grin MG311_xxx; OLD 100 mm; 3/8×26 TPI axle; 2250 g

Pole pairs
8
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
11:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Voltage, current and drivetrain

  • internal Reduction: 11 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • magnet Construction: surfaceG310/G311 rotor construction, including the 2021 stronger-adhesive update. Grin describes magnets bonded onto the rotor and lifting toward the stator if the adhesive fails.Source 1
Grin Technologies

GMAC

3 configurations

View configurations and sources
Manufacturer stocks GMAC as 8T and 10T winding options. Winding-specific electrical characteristics remain separate. The manufacturer GMAC drawing is supporting source history, not another motor revision. Physical and geared controller-effective pole counts remain separately labeled.
Grin Technologies

GMAC

10T standard winding

Pole pairs
80
Controller-effective; includes gearing
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3900
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
  • power Rating Core Temperature C: 110 °CCurrent GMAC family power-rating basis, not a stated maximum motor temperature or shutdown. Continuous power assumes steady-state 110 C core, room-temperature ambient and airflow corresponding to a 26-inch wheel. Five-minute power starts at 60 C and ends at 110 C. Published values at 100/200/300/400 rpm are 250/500/800/1000 W continuous and 670/1300/2000/2600 W for five minutes. Not transferred to the older drawing-only record.Source 1
Grin Technologies

GMAC

8T fast winding

Pole pairs
80
Controller-effective; includes gearing
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3900
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
  • power Rating Core Temperature C: 110 °CCurrent GMAC family power-rating basis, not a stated maximum motor temperature or shutdown. Continuous power assumes steady-state 110 C core, room-temperature ambient and airflow corresponding to a 26-inch wheel. Five-minute power starts at 60 C and ends at 110 C. Published values at 100/200/300/400 rpm are 250/500/800/1000 W continuous and 670/1300/2000/2600 W for five minutes. Not transferred to the older drawing-only record.Source 1
Grin Technologies

GMAC

10 mm splined rear axle; OLD 137 mm; Higo L1019

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
5:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 5 input-revolutions/output-revolutionmotor rotor to output shaft
Grin Technologies

Max45 All-Axle Front

2 configurations

View configurations and sources
Manufacturer identifies Max45 Front as one mechanical model with winding choices. Do not merge the 27 mm All-Axle or rear motor.
Grin Technologies

Max45 All-Axle Front

Max45 All-Axle · Front slow 5T SKU M-AA4505F

Pole pairs
23
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
45 mm stator stack length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
  • Temperature rating: recommended core upper temperature range: 110–120 °CManufacturer recommends keeping the Max45 front motor core under 110–120 C. This is operating guidance, not a hard shutdown, continuous power guarantee or absolute destruction temperature. Applies to standard and slow front windings covered by this manual. The online result has a stale V3 Rear title but the indexed document body explicitly identifies Max45 Front Rev 1.Source 1
  • Stator stack length: 45 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

Max45 All-Axle Front

Max45 All-Axle · Front standard 4T SKU M-AA4504F

Pole pairs
23
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
45 mm stator stack length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B~3450
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
  • Temperature rating: recommended core upper temperature range: 110–120 °CManufacturer recommends keeping the Max45 front motor core under 110–120 C. This is operating guidance, not a hard shutdown, continuous power guarantee or absolute destruction temperature. Applies to standard and slow front windings covered by this manual. The online result has a stale V3 Rear title but the indexed document body explicitly identifies Max45 Front Rev 1.Source 1
  • Stator stack length: 45 mmSource 1

Configuration notes

  • Manufacturer separately identifies front, rear, Max45 and generation-specific mechanical models. Same All-Axle name does not identify mounting, stator width or sensor revision.
Grin Technologies

MeZeeXXXRC

Grin eZee rear cassette; 11-speed freehub; two-part casing; OLD 137 mm; 3940 g

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Hub
Magnet / stator size
Not published
Extra gear reduction
5:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 5 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubWheel-hub placement established by visual review of the exact original engineering drawing, including fixed axle and wheel/rim integration. This establishes placement only; magnet construction remains unconfirmed.Source 1
Grin Technologies

Shengyi SX1

Grin front helical geared hub; OLD 100 mm; 3.0 kg

Pole pairs
15
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
4.83:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B3450
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 4.83 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
Grin Technologies

Shengyi SX2

Grin rear helical geared hub; OLD 136.8 mm; 3.2 kg

Pole pairs
15
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Geared hub
Magnet / stator size
Not published
Extra gear reduction
4.83:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
10K NTC B3450
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Voltage, current and drivetrain

  • internal Reduction: 4.83 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: hubExact product description or engineering drawing explicitly identifies a hub.Source 1
KO Moto

Big Block

Sur-Ron / Segway X260; 160x62 mm stator

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
62 mm stator stack length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • untyped manufacturer power: 40 kWSource POWER label does not identify continuous or peak duty.

Speed ratings

  • Not published

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Temperature rating: magnet material rating: 180 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: copper winding material rating: 220 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Power: untyped manufacturer power: 40 kWSource POWER label does not identify continuous or peak duty.Source 1
  • Stator stack length: 62 mmSource 1
KO Moto

RS

Sur-Ron / Segway X260; 160x53 mm stator

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
53 mm stator stack length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
35 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • untyped manufacturer power: 35 kWSource POWER label does not identify continuous or peak duty.
  • peak: 35 kWExplicit peak wording on manufacturer motor page and combo motor subsection

Speed ratings

  • Not published

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Temperature rating: magnet material rating: 150 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: copper winding material rating: 220 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Power: untyped manufacturer power: 35 kWSource POWER label does not identify continuous or peak duty.Source 1
  • Peak power: 35 kWExplicit peak wording on manufacturer motor page and combo motor subsectionSource 1 · Source 2
  • Stator stack length: 53 mmSource 1
Kunray

KR10

2 configurations · Hall or Encoder

View configurations and sources
Manufacturer explicitly identifies KR10H and KR10E as the same housing, dimensions, performance and installation interface, with Hall versus encoder feedback. KR10 is the platform name. Feedback connectors are different.
Kunray

KR10

72 V; manufacturer states Hall and encoder versions share output and temperature sensor

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Confirmed from rotor images
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
6.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
12.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY84-130
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6.5 kW
  • peak: 12.5 kW

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 6.5 kWSource 1
  • Peak power: 12.5 kWSource 1
  • Position sensor: HallSource 1
  • Temperature sensor: KTY84-130Source 1
  • Pole pairs: 5Source 1
  • Ingress protection: IP54Source 1
  • insulation Class Temperature: 155 °CSource 1
  • cooling: airSource 1
  • magnet Construction: ipmKR10 product family, including the KR10E encoder option on the same manufacturer page. The labelled V-magnet rotor artwork shows magnets buried in rotor slots. This does not establish construction for MY1020 motors.Source 1 · Source 2
Kunray

KR10E

72 V; manufacturer states Hall and encoder versions share output and temperature sensor

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Confirmed from rotor images
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
6.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
12.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY84-130
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6.5 kW
  • peak: 12.5 kW

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 6.5 kWSource 1
  • Peak power: 12.5 kWSource 1
  • Position sensor: encoderSource 1
  • Temperature sensor: KTY84-130Source 1
  • Pole pairs: 5Source 1
  • Ingress protection: IP54Source 1
  • insulation Class Temperature: 155 °CSource 1
  • cooling: airSource 1
  • magnet Construction: ipmKR10 product family, including the KR10E encoder option on the same manufacturer page. The labelled V-magnet rotor artwork shows magnets buried in rotor slots. This does not establish construction for MY1020 motors.Source 1 · Source 2
Kunray

KR5V v2

KR5V V2 · 72 V; KR5V-35-9T family; revised housing; programmable external controller

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY84-130
Position sensor options
Not published
Operating / winding temperatures
65 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 10 kW

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Magnet construction: IPMSource 1
  • Rated power: 5 kWSource 1
  • Peak power: 10 kWSource 1
  • Temperature sensor: KTY84-130Source 1
  • Pole pairs: 5Source 1
  • Ingress protection: IP54Source 1
  • insulation Class Temperature: 155 °CSource 1
  • cooling: airSource 1
  • manufacturer Operating Temperature Ceiling: 65 °CManufacturer says stay under 65 C / 150 F; sensor location/basis unspecified. Not a verified factory shutdown setting.Source 1
Kunray

MY1020

8 configurations

View configurations and sources
Manufacturer lists these as voltage/power configurations of one named product family. Preserve winding, dimensions, sensors and ratings per option. This grouping does not prove identical hardware across power sizes or establish aliases with other manufacturers or MY suffixes.
Kunray

MY1020

General BLDC listing; 36 V / 1000 W / 3100 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 48 V / 1000 W / 3500 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 48 V / 1500 W / 3750 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Kunray sells this voltage/power option on the same general MY1020 product listing as the identified 48 V 2000 W specimen whose teardown exposes surface magnet tiles. The factory 1500/1600/2000/2500 W dimension drawing further supports shared mechanical architecture.

  • Different winding, stack length or production revision could change the rotor.
  • The teardown directly establishes only the labeled 48 V 2000 W specimen.
  • Not transferred to MY1020D, MY1020-WG, HotPaxx or other brands; no pole count is inferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Posts 9, 11 and 14 by the same firsthand owner, April 2019: named Kunray MY1020 48 V 2000 W 42 A 4300 RPM; complete disassembly; body measured 134 mm long by 107 mm diameter. · Personally inspected label: Kun ray BLDC MY1020, 48 V DC, 2000 W, 42 A, 4300 r/min. · Personally inspected removed rotor: exposed curved magnet tiles outside the rotor core, two axial rows, retained by steel bands. · Personally inspected second rotor view confirms separate magnet tiles facing the air gap, with no iron pole face covering them. · Exact general MY1020 product option: 48 V, 2000 W, 42 A, 4300 RPM. Embedded manufacturer drawing links the 2000 W version to 107 mm body diameter and 134 mm body length. · Personally inspected factory drawing labelled 1500W/1600W/2000W/2500W: body diameter phi107, body length 134, overall length 166 +/-1; 95 +/-0.11 is mounting-hole spacing. This matches the teardown specimen dimensions and explains the conflicting 95 mm diameter in the page text.

FarDriver AN guidance

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 48 V / 1600 W / 3900 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Kunray sells this voltage/power option on the same general MY1020 product listing as the identified 48 V 2000 W specimen whose teardown exposes surface magnet tiles. The factory 1500/1600/2000/2500 W dimension drawing further supports shared mechanical architecture.

  • Different winding, stack length or production revision could change the rotor.
  • The teardown directly establishes only the labeled 48 V 2000 W specimen.
  • Not transferred to MY1020D, MY1020-WG, HotPaxx or other brands; no pole count is inferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Posts 9, 11 and 14 by the same firsthand owner, April 2019: named Kunray MY1020 48 V 2000 W 42 A 4300 RPM; complete disassembly; body measured 134 mm long by 107 mm diameter. · Personally inspected label: Kun ray BLDC MY1020, 48 V DC, 2000 W, 42 A, 4300 r/min. · Personally inspected removed rotor: exposed curved magnet tiles outside the rotor core, two axial rows, retained by steel bands. · Personally inspected second rotor view confirms separate magnet tiles facing the air gap, with no iron pole face covering them. · Exact general MY1020 product option: 48 V, 2000 W, 42 A, 4300 RPM. Embedded manufacturer drawing links the 2000 W version to 107 mm body diameter and 134 mm body length. · Personally inspected factory drawing labelled 1500W/1600W/2000W/2500W: body diameter phi107, body length 134, overall length 166 +/-1; 95 +/-0.11 is mounting-hole spacing. This matches the teardown specimen dimensions and explains the conflicting 95 mm diameter in the page text.

FarDriver AN guidance

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 48 V / 2000 W / 4300 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets
Confirmed from rotor images
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • advertised Power: 2 kWListed power, without continuous/peak qualificationSource 1
  • voltage: 48 VSource 1
  • listed Speed: 4,300 RPMSource 1
  • Drive type: midSource 1
  • magnet Construction: surfaceKunray MY1020 general BLDC option, 48 V / 2000 W / 42 A / 4300 RPM: exposed surface magnets are directly visible in a named firsthand 2019 teardown. The label ratings and 107 x 134 mm body match the current factory option and its dimension drawing. Evidence applies to this photographed configuration, not all production years or other MY1020 voltage/power options, MY1020D, MY1020-WG, HotPaxx upgrades, or other brands. No pole count is inferred from magnet-piece count; two axial rows are not separate pole pairs.Source 1 · Source 2 · Source 3 · Source 4 · Source 5 · Source 6

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 60 V / 2000 W / 4250 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Kunray sells this voltage/power option on the same general MY1020 product listing as the identified 48 V 2000 W specimen whose teardown exposes surface magnet tiles. The factory 1500/1600/2000/2500 W dimension drawing further supports shared mechanical architecture.

  • Different winding, stack length or production revision could change the rotor.
  • The teardown directly establishes only the labeled 48 V 2000 W specimen.
  • Not transferred to MY1020D, MY1020-WG, HotPaxx or other brands; no pole count is inferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Posts 9, 11 and 14 by the same firsthand owner, April 2019: named Kunray MY1020 48 V 2000 W 42 A 4300 RPM; complete disassembly; body measured 134 mm long by 107 mm diameter. · Personally inspected label: Kun ray BLDC MY1020, 48 V DC, 2000 W, 42 A, 4300 r/min. · Personally inspected removed rotor: exposed curved magnet tiles outside the rotor core, two axial rows, retained by steel bands. · Personally inspected second rotor view confirms separate magnet tiles facing the air gap, with no iron pole face covering them. · Exact general MY1020 product option: 48 V, 2000 W, 42 A, 4300 RPM. Embedded manufacturer drawing links the 2000 W version to 107 mm body diameter and 134 mm body length. · Personally inspected factory drawing labelled 1500W/1600W/2000W/2500W: body diameter phi107, body length 134, overall length 166 +/-1; 95 +/-0.11 is mounting-hole spacing. This matches the teardown specimen dimensions and explains the conflicting 95 mm diameter in the page text.

FarDriver AN guidance

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 60 V / 2500 W / 4400 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Construction inference and conditional AN guidance

Kunray sells this voltage/power option on the same general MY1020 product listing as the identified 48 V 2000 W specimen whose teardown exposes surface magnet tiles. The factory 1500/1600/2000/2500 W dimension drawing further supports shared mechanical architecture.

  • Different winding, stack length or production revision could change the rotor.
  • The teardown directly establishes only the labeled 48 V 2000 W specimen.
  • Not transferred to MY1020D, MY1020-WG, HotPaxx or other brands; no pole count is inferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Posts 9, 11 and 14 by the same firsthand owner, April 2019: named Kunray MY1020 48 V 2000 W 42 A 4300 RPM; complete disassembly; body measured 134 mm long by 107 mm diameter. · Personally inspected label: Kun ray BLDC MY1020, 48 V DC, 2000 W, 42 A, 4300 r/min. · Personally inspected removed rotor: exposed curved magnet tiles outside the rotor core, two axial rows, retained by steel bands. · Personally inspected second rotor view confirms separate magnet tiles facing the air gap, with no iron pole face covering them. · Exact general MY1020 product option: 48 V, 2000 W, 42 A, 4300 RPM. Embedded manufacturer drawing links the 2000 W version to 107 mm body diameter and 134 mm body length. · Personally inspected factory drawing labelled 1500W/1600W/2000W/2500W: body diameter phi107, body length 134, overall length 166 +/-1; 95 +/-0.11 is mounting-hole spacing. This matches the teardown specimen dimensions and explains the conflicting 95 mm diameter in the page text.

FarDriver AN guidance

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020

General BLDC listing; 72 V / 3000 W / 4900 RPM

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020-WG

2 configurations

View configurations and sources
Manufacturer lists these as voltage/power configurations of one named product family. Preserve winding, dimensions, sensors and ratings per option. This grouping does not prove identical hardware across power sizes or establish aliases with other manufacturers or MY suffixes.
Kunray

MY1020-WG

Sensor-equipped; 48 V / 2000 W; standard or heat sink; NS12 kit offered

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
product Image: KTY84-130 · text: KTY83-120 · Conflicting sources — do not use
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020-WG

Sensor-equipped; 72 V / 3000 W; standard or heat sink; NS12 kit offered

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
product Image: KTY84-130 · text: KTY83-120 · Conflicting sources — do not use
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

8 configurations

View configurations and sources
Manufacturer lists these as voltage/power configurations of one named product family. Preserve winding, dimensions, sensors and ratings per option. This grouping does not prove identical hardware across power sizes or establish aliases with other manufacturers or MY suffixes.
Kunray

MY1020D

36 V / 1000 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

48 V / 1000 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

48 V / 1500 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

48 V / 1600 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1.6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.6 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

48 V / 2000 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

60 V / 2000 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

60 V / 2500 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2.5 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1020D

72 V / 3000 W; D-suffix manufacturer listing

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Kunray

MY1030

7 configurations

View configurations and sources
Manufacturer lists these as voltage/power configurations of one named product family. Preserve winding, dimensions, sensors and ratings per option. This grouping does not prove identical hardware across power sizes or establish aliases with other manufacturers or MY suffixes.
Kunray

MY1030

36 V / 1000 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
1.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW
  • peak: 1.5 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 1 kWSource 1
  • Peak power: 1.5 kWPeak duration unspecifiedSource 1
  • voltage: 36 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

48 V / 1000 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
1.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW
  • peak: 1.5 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 1 kWSource 1
  • Peak power: 1.5 kWPeak duration unspecifiedSource 1
  • voltage: 48 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

48 V / 1600 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
1.6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.6 kW
  • peak: 2.5 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 1.6 kWSource 1
  • Peak power: 2.5 kWPeak duration unspecifiedSource 1
  • voltage: 48 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

48 V / 2000 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2.8 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW
  • peak: 2.8 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 2 kWSource 1
  • Peak power: 2.8 kWPeak duration unspecifiedSource 1
  • voltage: 48 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

60 V / 2000 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2.8 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW
  • peak: 2.8 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 2 kWSource 1
  • Peak power: 2.8 kWPeak duration unspecifiedSource 1
  • voltage: 60 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

60 V / 2500 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
3 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2.5 kW
  • peak: 3 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 2.5 kWSource 1
  • Peak power: 3 kWPeak duration unspecifiedSource 1
  • voltage: 60 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Kunray

MY1030

72 V / 3000 W; manufacturer September 2026 configuration table

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
4 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW
  • peak: 4 kWPeak duration unspecified

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 3 kWSource 1
  • Peak power: 4 kWPeak duration unspecifiedSource 1
  • voltage: 72 VSource 1
  • Temperature sensor: KTY83-122Manufacturer explicitly says this sensor is standard across the MY1030 rangeSource 1
  • Magnet construction: IPMCurrent MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Pole pairs: 5Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
  • Temperature sensor: KTY83-122Current MY1030 product family; seven variants are listed on the same manufacturer page. This does not cover MY1020, MY1020-WG or MY1020D.Source 1 · Source 2
Lunyee

BM1109/MY1020D

1000 W; table voltage options [36, 48]

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Lunyee

BM1109/MY1020D

2000 W; table voltage options [60]

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Motenergy

ME0907

Pole pairs
4
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
5,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY84-130
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • maximum: 5,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • operating Voltage: 0–72 Vcontroller dc input
  • continuous Current: 100 Aunspecified · Current amplitude convention not specified · Unconfirmed
  • continuous Current: 80 Aphase · Current amplitude convention not specified · Unconfirmed
  • peak Current: 220 Aphase · Current amplitude convention not specified · 60 seconds

Published specifications and qualifications

  • Magnet construction: SPMManufacturer category explicitly states surface-mount magnet rotors and lists exact modelSource 1
Motenergy

ME1117

Pole pairs
4
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
5,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
unspecified
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • maximum: 5,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • operating Voltage: 0–72 Vcontroller dc input
  • continuous Current: 120 Aunspecified · Current amplitude convention not specified · Unconfirmed
  • continuous Current: 80 Aphase · Current amplitude convention not specified · Unconfirmed
  • peak Current: 220 Aphase · Current amplitude convention not specified · 60 seconds

Published specifications and qualifications

  • Magnet construction: SPMManufacturer category explicitly states surface-mount magnet rotors and lists exact modelSource 1
Motenergy

ME1118

Pole pairs
4
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
5,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
unspecified
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • maximum: 5,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • operating Voltage: 0–96 Vcontroller dc input
  • continuous Current: 80 Aunspecified · Current amplitude convention not specified
  • continuous Current: 80 Aphase · Current amplitude convention not specified
  • peak Current: 220 Aphase · Current amplitude convention not specified · 60 seconds

Published specifications and qualifications

  • Magnet construction: SPMManufacturer category explicitly states surface-mount magnet rotors and lists exact modelSource 1
Motenergy

ME1716

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY84-130
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • limiting: 6,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • continuous Current: 100 Aunspecified · Current amplitude convention not specified
  • maximum Current: 300 Aunspecified · Current amplitude convention not specified · 120 seconds
  • continuous Current: 100 Aunspecified · Current amplitude convention not specified

Published specifications and qualifications

  • Magnet construction: SPMExact-model breadcrumb places this product under Radial Air Gap PMSM Motors – Surface Magnets. Common navigation is not used.Source 1
  • Temperature rating: magnet material rating: 180 °C (N38UH magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
Motenergy

ME1717

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY84-130
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • limiting: 6,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • continuous Current: 100 Aunspecified · Current amplitude convention not specified
  • maximum Current: 300 Aunspecified · Current amplitude convention not specified · 120 seconds
  • continuous Current: 100 Aunspecified · Current amplitude convention not specified

Published specifications and qualifications

  • Magnet construction: SPMExact-model breadcrumb places this product under Radial Air Gap PMSM Motors – Surface Magnets. Common navigation is not used.Source 1
  • Temperature rating: magnet material rating: 180 °C (N38UH magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
Motenergy

ME1718

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
6 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
4,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY84-130
Position sensor options
Not published
Operating / winding temperatures
maximum winding temperature: 170 °C (windings)
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 6 kWS1 duty

Speed ratings

  • manufacturer rated: 4,000 RPMShaft reference not specified · S1 duty
  • limiting: 6,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • continuous Current: 100 Aunspecified · Current amplitude convention not specified
  • maximum Current: 300 Aunspecified · Current amplitude convention not specified · 120 seconds
  • continuous Current: 100 Aunspecified · Current amplitude convention not specified

Published specifications and qualifications

  • Magnet construction: SPMExact-model breadcrumb places this product under Radial Air Gap PMSM Motors – Surface Magnets. Common navigation is not used.Source 1
  • Temperature rating: magnet material rating: 180 °C (N38UH magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum winding temperature: 170 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
Motenergy

ME1719

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
6 kW
See source conditions below
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
4,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY84-130
Position sensor options
Hall
Operating / winding temperatures
maximum winding temperature: 170 °C (windings)
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 6 kWS1 duty

Speed ratings

  • manufacturer rated: 4,000 RPMShaft reference not specified · S1 duty
  • limiting: 6,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • continuous Current: 100 Aunspecified · Current amplitude convention not specified
  • maximum Current: 300 Aunspecified · Current amplitude convention not specified · 120 seconds
  • continuous Current: 100 Aunspecified · Current amplitude convention not specified

Published specifications and qualifications

  • Magnet construction: SPMExact-model breadcrumb places this product under Radial Air Gap PMSM Motors – Surface Magnets. Common navigation is not used.Source 1
  • Temperature rating: magnet material rating: 180 °C (N38UH magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum winding temperature: 170 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
Motenergy

ME2009

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · limiting · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY84-130
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • limiting: 6,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • continuous Current: 150 Aunspecified · Current amplitude convention not specified
  • maximum Current: 450 Aunspecified · Current amplitude convention not specified · 120 seconds
  • continuous Current: 150 Aunspecified · Current amplitude convention not specified

Published specifications and qualifications

  • Magnet construction: SPMExact-model breadcrumb places this product under Radial Air Gap PMSM Motors – Surface Magnets. Common navigation is not used.Source 1
  • Temperature rating: magnet material rating: 180 °C (N38UH magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
QS Motor

QS120 38H

QS Motor D120C-45 PMSM 1500W Encoder Sensor Mid Drive Motor

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
38 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
2,600 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 180 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • manufacturer rated: 2,600 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 180 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 38 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS120 v1 70H

QSD120A-70

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
70 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
2,800 RPM · unspecified · shaft reference unspecified
4,400 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 2,800 RPMShaft reference not specified · Load/rating basis not stated
  • unspecified: 4,400 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 250 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 60 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 140 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM120 V1 70H 2000W; belt/spline; exact model in kit tableSource 1 · Source 2
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS120 v3 60H

QSJ120C-60

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
60 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
2,800 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • manufacturer rated: 2,800 RPMShaft reference not specified

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ120C-60 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • peak Current: 80 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM120 V3 2000W geared spline card; QSJ120C-60 2000W named kit table. QS Presentation p10 has a different 2500W 120 V3 70H, not usedSource 1 · Source 2
  • Magnet height: 60 mmSource 1 · Source 2

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ120C-60 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS128

QSJ128B-70

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
3.462:1
Multiply by the external sprocket or belt ratio
Rated power
4.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10.5 kW · maximum
Published label; duration and conditions in source details
Rated RPM
4,800 RPM · motor rotor · Conflicting sources — do not use
Maximum / peak RPM
Not published
Other published RPM
4,800 RPM · no load · motor rotor · Conflicting sources — do not use
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum winding temperature: 150 °C (windings)
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4.5 kW
  • maximum: 10.5 kW

Speed ratings

  • manufacturer rated: 4,800 RPMmotor rotor · Conflicting sources — do not use
  • no load: 4,800 RPMmotor rotor · Conflicting sources — do not use

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 72 Vmotor
  • internal Reduction: 3.462 input-revolutions/output-revolutionmotor rotor to output shaft
  • internal Reduction: 3.462 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: maximum winding temperature: 150 °C (windings)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ128B-70 kit-catalog table publishes 3.462:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS128 (QSD128A-60)

QSD128A-60 · Natural-cooled; encoder

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
5.2 kW · peak
Published label; duration and conditions in source details
Rated RPM
2,800 RPM · shaft reference unspecified
Maximum / peak RPM
4,500 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum winding temperature: 150 °C (winding)
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 5.2 kWFactory article; peak duration and input/shaft basis unspecified.
  • Manufacturer rated: 2.5 kW

Speed ratings

  • manufacturer rated: 2,800 RPMShaft reference not specified · 72 V
  • maximum: 4,500 RPMShaft reference not specified · 72 V; Factory maximum speed; load and field-weakening conditions not stated.

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature sensor: KTY83-122Factory article identifies the fitted sensor; a controller conversion profile is not established here.Source 1
  • Rated power: 2.5 kWSource 1
  • Power: peak: 5.2 kWFactory article; peak duration and input/shaft basis unspecified.Source 1
  • voltage: 72 VPublished system voltage.Source 1
  • Drive type: mid-driveSource 1
  • cooling: natural coolingSource 1
  • Ingress protection: IP67Source 1
  • Insulation class: FInsulation class is not a motor operating-temperature limit or protection setting.Source 1
  • Pole pairs: 4Source 1
  • rated Torque: 7 N·mSource 1
  • maximum Torque: 58 N·mSource 1
  • controller Bus Current Limit: 80 AFactory controller matching limit; not continuous motor winding current.Source 1
  • controller Peak Phase Current: 260 AFactory matching specification; amplitude convention and duration are not stated.Source 1
  • phase Cable Area: 6 mm²Source 1
  • duty Cycle: S9Manufacturer duty designation; rated power is not relabelled as a continuous rating.Source 1
  • Temperature rating: maximum winding temperature: 150 °C (winding)Factory winding limit; not a controller shutdown setting.Source 1
  • overload Description: Twice rated power · Conflicting sources — do not useRow is labelled short-time overload but its parameter says continuous operation; duration is unspecified. No continuous-power value is inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • Pole pairs, exact continuous power and numeric protection settings are not established by this article.
QS Motor

QS138 (QSJ138F-50)

QSJ138F-50 · Geared mid-drive; manufacturer kit catalog

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
5,200 RPM · unspecified · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 5,200 RPMmotor rotor · Published as rated/basic RPM before reduction; load-rating semantics not distinguished.

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Rated power: 2 kWSource 1
  • rated Voltage: 72 VSource 1
  • Drive type: mid-driveSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ138F-50 kit-catalog table publishes 2.368:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Exact kit-catalog model code; not merged with other QS variants. Version, magnet height, pole pairs, temperature sensor, and protection thresholds are not established by this table.
  • Rated/basic RPM is quoted before reduction. Load rating and maximum speed are not established; do not substitute it for rated or maximum RPM.
QS Motor

QS138 (QSJ138H-70)

QSJ138H-70 · Geared mid-drive; manufacturer kit catalog

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
5,100 RPM · unspecified · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • unspecified: 5,100 RPMmotor rotor · Published as rated/basic RPM before reduction; load-rating semantics not distinguished.

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Rated power: 3 kWSource 1
  • rated Voltage: 72 VSource 1
  • Drive type: mid-driveSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ138H-70 kit-catalog table publishes 2.368:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Exact kit-catalog model code; not merged with other QS variants. Version, magnet height, pole pairs, temperature sensor, and protection thresholds are not established by this table.
  • Rated/basic RPM is quoted before reduction. Load rating and maximum speed are not established; do not substitute it for rated or maximum RPM.
QS Motor

QS138 (QSJ138M-60)

QSJ138M-60 · Geared mid-drive; manufacturer kit catalog

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.94:1
Multiply by the external sprocket or belt ratio
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
5,000 RPM · unspecified · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • unspecified: 5,000 RPMmotor rotor · Published as rated/basic RPM before reduction; load-rating semantics not distinguished.

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • internal Reduction: 2.94 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Rated power: 5 kWSource 1
  • rated Voltage: 72 VSource 1
  • Drive type: mid-driveSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ138M-60 kit-catalog table publishes 2.94:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Exact kit-catalog model code; not merged with other QS variants. Version, magnet height, pole pairs, temperature sensor, and protection thresholds are not established by this table.
  • Rated/basic RPM is quoted before reduction. Load rating and maximum speed are not established; do not substitute it for rated or maximum RPM.
QS Motor

QS138 100H

QSD138A-100

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
100 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
20 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
8,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
maximum operating temperature: 50 °C
maximum working temperature: 150 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW
  • peak: 20 kW

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified
  • peak: 8,000 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 50 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 150 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 100 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 55H

QSJ138F-55

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
55 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,700 RPM · no load · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 180 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2.5 kW

Speed ratings

  • no load: 4,700 RPMShaft reference not specified

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ138F-55 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 120 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 180 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 55 mmSource 1 · Source 2

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ138F-55 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 60H

QSD138A-60

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
60 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
4,500 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 180 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2.5 kW

Speed ratings

  • manufacturer rated: 3,000 RPMShaft reference not specified
  • unspecified: 4,500 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 100 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 180 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 60 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 90H

QSD138D-90

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
7.5 kW
See source conditions below
Peak / maximum power
13.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,000 RPM · unspecified · shaft reference unspecified
6,500 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 13.5 kW
  • continuous: 7.5 kWMaximum continuous

Speed ratings

  • unspecified: 4,000 RPMShaft reference not specified · Load/rating basis not stated
  • unspecified: 6,500 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 200 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 89 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 90 mmSource 1 · Source 2 · Source 3

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v1 70H

QSD138A-70

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
70 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
3 kW · Conflicting sources — do not use
6 kW · Conflicting sources — do not use
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
3,800 RPM · base · shaft reference unspecified
6,000 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 10 kWShared manufacturer panel explicitly labels 138 V1 and V2 3kW. Peak duration and input/shaft basis unspecified. Separate rated-power conflict retained.
  • Manufacturer rated: 3 kW · Conflicting sources — do not useCurrent exact-model table says 3000W; linked web panel says 6000W. No conversion to continuous.
  • Manufacturer rated: 6 kW · Conflicting sources — do not useConflicts with panel image labels and current exact-model catalog 3000W.

Speed ratings

  • base: 3,800 RPMShaft reference not specified · 72 V; shared V1/V2 specification panel; mechanical maximum not stated.
  • unspecified: 6,000 RPMShaft reference not specified · 72 V with flux weakening; load and mechanical maximum not stated.

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM138 V1 70H 3000W; model identity and housing in kit table; manual p6 independently says IPMSource 1 · Source 2
  • Power: peak: 10 kWShared manufacturer panel explicitly labels 138 V1 and V2 3kW. Peak duration and input/shaft basis unspecified. Separate rated-power conflict retained.Source 1
  • Power: manufacturer rated: 3 kW · Conflicting sources — do not useCurrent exact-model table says 3000W; linked web panel says 6000W. No conversion to continuous.Source 1 · Source 2
  • Power: manufacturer rated: 6 kW · Conflicting sources — do not useConflicts with panel image labels and current exact-model catalog 3000W.Source 1 · Source 2
  • Temperature rating: working temperature range: 70–120 °CPublished motor thermal rating, not controller cutoff or recommended setpoint.Source 1
  • Temperature rating: peak temperature: 150 °CPublished motor thermal rating, not controller cutoff or recommended setpoint.Source 1
  • Magnet height: 70 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v1 90H

QSD138A-90

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
7.5 kW
See source conditions below
Peak / maximum power
13.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,000 RPM · unspecified · shaft reference unspecified
6,500 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 13.5 kW
  • continuous: 7.5 kWMaximum continuous

Speed ratings

  • unspecified: 4,000 RPMShaft reference not specified · Load/rating basis not stated
  • unspecified: 6,500 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof. Cross-check: Electro & Company separately offers a direct-drive QS138 90H and an optional V3 geared variant. That supports keeping these configurations distinct; the reseller page alone does not establish an exact QSD138A-90 revision.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 200 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 89 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM138 V1 90H 4000W direct drive; named kit model, distinct from geared/water-cooled 138Source 1 · Source 2
  • Magnet height: 90 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v2 70H

QSD138B-70

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
70 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
3 kW · Conflicting sources — do not use
6 kW · Conflicting sources — do not use
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
3,800 RPM · base · shaft reference unspecified
6,000 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 10 kWShared manufacturer panel explicitly labels 138 V1 and V2 3kW. Peak duration and input/shaft basis unspecified. Separate rated-power conflict retained.
  • Manufacturer rated: 3 kW · Conflicting sources — do not useCurrent exact-model table says 3000W; linked web panel says 6000W. No conversion to continuous.
  • Manufacturer rated: 6 kW · Conflicting sources — do not useConflicts with panel image labels and current exact-model catalog 3000W.

Speed ratings

  • base: 3,800 RPMShaft reference not specified · 72 V; shared V1/V2 specification panel; mechanical maximum not stated.
  • unspecified: 6,000 RPMShaft reference not specified · 72 V with flux weakening; load and mechanical maximum not stated.

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM138 V2 70H 3000W; model identity and housing in kit table; manual p6 independently says IPMSource 1 · Source 2
  • Power: peak: 10 kWShared manufacturer panel explicitly labels 138 V1 and V2 3kW. Peak duration and input/shaft basis unspecified. Separate rated-power conflict retained.Source 1
  • Power: manufacturer rated: 3 kW · Conflicting sources — do not useCurrent exact-model table says 3000W; linked web panel says 6000W. No conversion to continuous.Source 1 · Source 2
  • Power: manufacturer rated: 6 kW · Conflicting sources — do not useConflicts with panel image labels and current exact-model catalog 3000W.Source 1 · Source 2
  • Temperature rating: working temperature range: 70–120 °CPublished motor thermal rating, not controller cutoff or recommended setpoint.Source 1
  • Temperature rating: peak temperature: 150 °CPublished motor thermal rating, not controller cutoff or recommended setpoint.Source 1
  • Magnet height: 70 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v3 70H

QSJ138A-70

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
70 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
5.5 kW
See source conditions below
Peak / maximum power
11 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
2,955 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 11 kW
  • continuous: 5.5 kWMaximum continuous

Speed ratings

  • unspecified: 2,955 RPMShaft reference not specified · Load/rating basis not stated

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ138A-70 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference · Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 150 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 85 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM138 V3 70H 3000W geared card, exact named kit model; do not transfer new gear-ratio or speed figuresSource 1 · Source 2
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ138A-70 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v3 90H (QSJ138D-90)

QSJ138D-90

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
13.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,800 RPM · unspecified · shaft reference unspecified
7,000 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 13.5 kW

Speed ratings

  • unspecified: 4,800 RPMShaft reference not specified · Load/rating basis not stated
  • unspecified: 7,000 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ138D-90 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 200 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 60 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM138 V3 90H 4000W geared air-cooled card; named kit model and housingSource 1 · Source 2
  • Magnet height: 90 mmSource 1

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ138D-90 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS138 v3 90H (QSJ138J-90)

QSJ138J-90

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
7.5 kW
See source conditions below
Peak / maximum power
13.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,100 RPM · unspecified · shaft reference unspecified
7,000 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 13.5 kW
  • continuous: 7.5 kWMaximum continuous

Speed ratings

  • unspecified: 4,100 RPMShaft reference not specified · Load/rating basis not stated
  • unspecified: 7,000 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ138J-90 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 200 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • rated Current: 60 Aunspecified · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use. · Unconfirmed
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPMManufacturer IPM panel depicts the 4000 W water-cooled 138 90H V3 geared motor. Exact QSJ138J-90 WaterCooling part and matching photograph appear on kit PDF page 5. Rendered pages visually reviewed; do not transfer to gearless QSD138D-90.Source 1 · Source 2
  • Magnet height: 90 mmSource 1

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ138J-90 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS155 (QSJ155A-46)

QSJ155A-46 · Geared mid-drive; manufacturer kit catalog

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.94:1
Multiply by the external sprocket or belt ratio
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,700 RPM · unspecified · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • unspecified: 4,700 RPMmotor rotor · Published as rated/basic RPM before reduction; load-rating semantics not distinguished.

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • internal Reduction: 2.94 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Rated power: 5 kWSource 1
  • rated Voltage: 72 VSource 1
  • Drive type: mid-driveSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ155A-46 kit-catalog table publishes 2.94:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Exact kit-catalog model code; not merged with other QS variants. Version, magnet height, pole pairs, temperature sensor, and protection thresholds are not established by this table.
  • Rated/basic RPM is quoted before reduction. Load rating and maximum speed are not established; do not substitute it for rated or maximum RPM.
QS Motor

QS155 36H (D155A-36)

QS Motor D155A-36 72V 5000 Watts Electric Hairpin Motor

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
36 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
15 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
8,000 RPM · with flux weakening · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum operating ambient temperature: 50 °C (ambient air)
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 15 kW

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified
  • unspecified: 8,000 RPMShaft reference not specified · Flux weakening; load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: maximum operating ambient temperature: 50 °C (ambient air)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: maximum coil temperature resistance: 180 °C (coil)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: enamelled wire temperature resistance: 180 °C (wire)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Magnet height: 36 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS155 36H (QSJ155A-36)

QSJ155A-36

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
36 mm magnet height
Extra gear reduction
2.94:1
Multiply by the external sprocket or belt ratio
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
12.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
2,075 RPM · shaft reference unspecified
Maximum / peak RPM
2,720 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 150 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 12.5 kW

Speed ratings

  • manufacturer rated: 2,075 RPMShaft reference not specified
  • peak: 2,720 RPMShaft reference not specified

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • internal Reduction: 2.94 input-revolutions/output-revolutionmotor rotor to output shaft
  • internal Reduction: 2.94 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 150 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPMJ155A-36 explicitly named IPM 5000W; exact QSJ155A-36 kit tableSource 1 · Source 2
  • Magnet height: 36 mmSource 1 · Source 2

Configuration notes

  • The exact QSJ155A-36 kit-catalog table publishes 2.94:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS155 70H

QSD155A-70

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
70 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
10 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
25 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
8,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum operating temperature: 50 °C
maximum working temperature: 150 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW
  • peak: 25 kW

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified
  • peak: 8,000 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff. QS's model-specific QSD155A-70 article separately corroborates a 150 C maximum working temperature and the KTY83/122 sensor. That working limit is not a published controller shutdown threshold.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 50 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 150 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPMD155A-36/70 explicitly named IPM; exact QSD155A-70 10000W kit tableSource 1 · Source 2
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS159.8 60H

QS159.8

Pole pairs
20
Physical rotor unless stated
Magnet construction
Surface magnets
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Direct-drive hub
Magnet / stator size
60 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
550 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW
  • peak: 2 kW

Speed ratings

  • unspecified: 550 RPMShaft reference not specified · Load/rating basis not stated

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS165 (QSJ165D-35)

QSJ165D-35 · Geared mid-drive; manufacturer kit catalog

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
4.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
5,700 RPM · unspecified · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4.5 kW

Speed ratings

  • unspecified: 5,700 RPMmotor rotor · Published as rated/basic RPM before reduction; load-rating semantics not distinguished.

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Rated power: 4.5 kWSource 1
  • rated Voltage: 72 VSource 1
  • Drive type: mid-driveSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.

Configuration notes

  • The exact QSJ165D-35 kit-catalog table publishes 2.368:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Exact kit-catalog model code; not merged with other QS variants. Version, magnet height, pole pairs, temperature sensor, and protection thresholds are not established by this table.
  • Rated/basic RPM is quoted before reduction. Load rating and maximum speed are not established; do not substitute it for rated or maximum RPM.
QS Motor

QS165 v1

QS165 · Encoder mid-drive

Pole pairs
7
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
8 kW · maximum
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
6,000 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • maximum: 8 kW

Speed ratings

  • unspecified: 6,000 RPMShaft reference not specified · Load/rating basis not stated

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: mid-driveExact-profile source title: Mid Drive Ebike Kit QS165 5000W Encoder PMSM Motor Kits with ND72490B 490A ControllerSource 1
  • magnet Construction: IPMOriginal 5000W QS165 V1. The 2023 manufacturer catalog explicitly labels the original 165 IPM and says V2 is still under development; matched to the V1 column in the manufacturer V1/V2 comparison. No magnet height is inferred.Source 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS165 v1 50H

QSD165D-50 · QS165 family; exact source configuration

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
50 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
10 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
6,200 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 150 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW

Speed ratings

  • manufacturer rated: 6,200 RPMShaft reference not specified
  • maximum: 10,000 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 150 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM165 V1 50H 10000W Hall/encoder card; named kit modelSource 1 · Source 2
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS165 v2 35H

QSD165B-35 · QS165 family; exact source configuration

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
35 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10 kW · maximum
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
5,000–6,500 RPM · no load · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • maximum: 10 kW

Speed ratings

  • no load: 5,000–6,500 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 72 Vmotor

Published specifications and qualifications

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS165 v3 30H

QSJ165D-30 · QS165 family; exact source configuration

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
30 mm magnet height
Extra gear reduction
2.368:1
Multiply by the external sprocket or belt ratio
Rated power
3.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
3,600 RPM · motor rotor
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
maximum operating temperature: 60 °C
maximum working temperature: 150 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3.5 kW

Speed ratings

  • manufacturer rated: 3,600 RPMmotor rotor

Gearbox evidence

Internal gearbox. Setup uses the exact QSJ165D-30 SiAECOSYS kit-catalog ratio of 2.368:1. The product-image value of 2.35:1 is retained in the source review.

Gearbox reference · Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • internal Reduction: 2.368 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: maximum operating temperature: 60 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Temperature rating: maximum working temperature: 150 °CManufacturer uses separate operating and working labels. Measurement locations and controller protection behavior are not specified.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • magnet Construction: IPMQS165 V3 3500W QSJ165D-30: manufacturer IPM catalog photo carries a readable 165D30 marking and matches the exact-model kit photo and product listing. The presentation caption says 35H; that conflicting height caption is not used to overwrite the exact-model 30H specification or to confirm QSJ165D-35.Source 1 · Source 2 · Source 3
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Setup uses 2.368:1 from the exact QSJ165D-30 table in the SiAECOSYS kit catalog. The product specification also publishes 2.35:1; that claim remains in the source review. This source choice does not establish a different physical gearbox revision or verify every historical unit.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS165 v3 60H

QSJ165A-60 · QS165 60H with 2.37:1 gearbox

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
60 mm magnet height
Extra gear reduction
2.37:1
Multiply by the external sprocket or belt ratio
Rated power
12 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
20 kW · maximum
Published label; duration and conditions in source details
Rated RPM
2,280 RPM · gearbox output
Maximum / peak RPM
3,165 RPM · maximum · gearbox output
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW
  • maximum: 20 kW

Speed ratings

  • manufacturer rated: 2,280 RPMgearbox output
  • maximum: 3,165 RPMgearbox output

Gearbox evidence

Exact model has published rotor-to-output reduction; retain all conflicting source values.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • internal Reduction: 2.37 input-revolutions/output-revolutionmotor rotor to output shaft
  • internal Reduction: 2.37 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Magnet height: 60 mmSource 1 · Source 2

Configuration notes

  • The exact QSJ165A-60 kit-catalog table publishes 2.37:1. This is the motor internal reduction; external sprocket or pulley reduction is additional.
  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS180 120H (QSD180C-120)

QSD180C-120 · Air-cooled hairpin; encoder

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
120 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
20 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
4,400 RPM · shaft reference unspecified
Maximum / peak RPM
7,000 RPM · with flux weakening · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY83-122
NTC 10K
KTY83-122 / NTC 10K
Position sensor options
Encoder
Operating / winding temperatures
maximum winding temperature: 150 °C (winding) · Conflicting sources — do not use
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 40 kWFactory article; peak duration and input/shaft basis unspecified.
  • Manufacturer rated: 20 kW

Speed ratings

  • manufacturer rated: 4,400 RPMShaft reference not specified · 72 V
  • maximum: 7,000 RPMShaft reference not specified · 72 V; After field weakening; mechanical overspeed limit not stated.

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Rated power: 20 kWSource 1
  • Power: peak: 40 kWFactory article; peak duration and input/shaft basis unspecified.Source 1
  • voltage: 72 VPublished system voltage.Source 1
  • Drive type: mid-driveSource 1
  • cooling: natural air coolingSource 1
  • Ingress protection: IP67Source 1
  • Insulation class: HInsulation class is not a motor operating-temperature limit or protection setting.Source 1
  • Pole pairs: 4Source 1
  • rated Torque: 36 N·mSource 1
  • maximum Torque: 235 N·mSource 1
  • controller Bus Current Limit: 600 AFactory controller matching limit; not continuous motor winding current.Source 1
  • controller Peak Phase Current: 1,600 AFactory matching specification; amplitude convention and duration are not stated.Source 1
  • phase Cable Area: 50 mm²Source 1
  • duty Cycle: S9Manufacturer duty designation; rated power is not relabelled as a continuous rating.Source 1
  • magnet Grade: 38UHSource 1
  • Temperature rating: maximum winding temperature: 150 °C (winding) · Conflicting sources — do not useWinding row gives Class F ≤150°C, with Class H withstand up to 180°C; the same table lists Class H insulation. Applicability of the 150°C operating limit needs clarification.Source 1
  • Temperature rating: insulation withstand temperature: 180 °C (winding insulation)Class H withstand note only; not a maximum operating temperature or controller cutoff.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 120 mmSource 1

Configuration notes

  • Pole pairs, exact continuous power and numeric protection settings are not established by this article.
QS Motor

QS180 90H

QS180

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
18 kW
Peak / maximum power
20 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
4,300–6,000 RPM · no load · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW
  • peak: 20 kW
  • continuous: 18 kW

Speed ratings

  • no load: 4,300–6,000 RPMShaft reference not specified

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • maximum Current: 300 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • maximum Current: 850 Aphase · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM180 8000W spline card; named QSD180A-90 8000W encoder model in kit table. QS Presentation p10 prints 190, so it is not the identity authoritySource 1 · Source 2
  • Magnet height: 90 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS180 90H (QSD180D-90)

QSD180D-90 · Liquid-cooled hairpin; encoder

Pole pairs
4
Physical rotor unless stated
Magnet construction
IPM
Catalog owner confirmation
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
90 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
20 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
8,500 RPM · with flux weakening · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
6,200 RPM · no load · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Encoder
Operating / winding temperatures
maximum winding temperature: 150 °C (winding) · Conflicting sources — do not use
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 40 kWFactory article; peak duration and input/shaft basis unspecified.
  • Manufacturer rated: 20 kW

Speed ratings

  • no load: 6,200 RPMShaft reference not specified · 72 V
  • maximum: 8,500 RPMShaft reference not specified · 72 V; High field weakening; mechanical overspeed limit not stated.

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature sensor: KTY83-122Factory article identifies the fitted sensor; a controller conversion profile is not established here.Source 1
  • Rated power: 20 kWSource 1
  • Power: peak: 40 kWFactory article; peak duration and input/shaft basis unspecified.Source 1
  • voltage: 72 VPublished system voltage.Source 1
  • Drive type: mid-driveSource 1
  • cooling: liquid-cooledSource 1
  • Ingress protection: IP67Source 1
  • Insulation class: HInsulation class is not a motor operating-temperature limit or protection setting.Source 1
  • Pole pairs: 4Source 1
  • rated Torque: 28 N·mSource 1
  • maximum Torque: 175 N·mSource 1
  • controller Bus Current Limit: 600 AFactory controller matching limit; not continuous motor winding current.Source 1
  • controller Peak Phase Current: 1,600 AFactory matching specification; amplitude convention and duration are not stated.Source 1
  • phase Cable Area: 50 mm²Source 1
  • duty Cycle: S9Manufacturer duty designation; rated power is not relabelled as a continuous rating.Source 1
  • magnet Grade: 38UHSource 1
  • Temperature rating: maximum winding temperature: 150 °C (winding) · Conflicting sources — do not useWinding row gives Class F ≤150°C, with Class H withstand up to 180°C; the same table lists Class H insulation. Applicability of the 150°C operating limit needs clarification.Source 1
  • Temperature rating: insulation withstand temperature: 180 °C (winding insulation)Class H withstand note only; not a maximum operating temperature or controller cutoff.Source 1
  • magnet Construction: IPM · Catalog owner confirmationIPM classification confirmed by the catalog owner on 2026-09-30. Exact-model manufacturer confirmation has not been independently verified.
  • Magnet height: 90 mmSource 1

Configuration notes

  • Pole pairs, exact continuous power and numeric protection settings are not established by this article.
QS Motor

QS205 v2 40H

QSMOTOR 205 20inch 1000W V2

Pole pairs
23
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
396 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 396 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW
  • peak: 6 kWfew seconds

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • continuous Current: 44 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • peak Current: 100 / 150 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
760 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW
  • peak: 6 kW

Speed ratings

  • unspecified: 760 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 40H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 40H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 40H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
800 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • unspecified: 800 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 60 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 40H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 45H

Single Shaft 10 inch 2000 Watt 72V V3 Electric Scooter Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 50H

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
14 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 14 kWManufacturer says could be 14000W peak in few seconds; conditional capability claim, unspecified exact seconds and input/shaft basis. 200mm dropout QS205 V3 spoke listing only.

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Power: peak: 14 kWManufacturer says could be 14000W peak in few seconds; conditional capability claim, unspecified exact seconds and input/shaft basis. 200mm dropout QS205 V3 spoke listing only.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 50H

QS Motor 205 Hub Motor 3000W 50H V3 Electric Bike Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,157 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW
  • peak: 6 kWfew seconds

Speed ratings

  • unspecified: 1,157 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • continuous Current: 44 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • peak Current: 100 / 150 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 50H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 6 kWExact 10-inch racing QS205 V3 50H 3000W product table; 72V. Peak duration and input/shaft basis not stated.
  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Power: peak: 6 kWExact 10-inch racing QS205 V3 50H 3000W product table; 72V. Peak duration and input/shaft basis not stated.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 50H

QS205

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3 55H

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
55 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 55 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS205 v3TI 50H

QS205

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
650 RPM · no load · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • no load: 650 RPMShaft reference not specified

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 30H

QS212

Pole pairs
26
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
800 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
540 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 800 W
  • peak: 2 kW

Speed ratings

  • unspecified: 540 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 60 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1 40H

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1.1

QSMOTOR 212 10inch 2000W

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
470 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 470 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1.12

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1.12

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1.12 30H

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
540 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • unspecified: 540 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 60 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v1.12 35H

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
2.4 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
450 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–110 °C
Location and conditions in source details
Suggested cutoff ceiling
110 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.2 kW
  • peak: 2.4 kW

Speed ratings

  • unspecified: 450 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–110 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v3

QSMOTOR 212 7000W V3

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
7 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,300 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 7 kW

Speed ratings

  • unspecified: 1,300 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v4

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v4

10 inch 7000 Watt V4 Wheel Hub 72V Motor for Racing Scooter

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
7 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 7 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v4 60H

QS212

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
60 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • kv: 13.4 / 16.8 / 19 / 22.5 manufacturer-KVShaft reference not specified · Select the ordered winding; shaft reference is not stated.

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 60 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS212 v4 70H

Racing Type 10 inch 3500W V4 72V Electric Scooter Hub Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
70 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS219 v1 40H

QS219

Pole pairs
30
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
3.6 kW · peak
Published label; duration and conditions in source details
Rated RPM
910 RPM · motor rotor
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW
  • peak: 3.6 kWfew seconds

Speed ratings

  • manufacturer rated: 910 RPMmotor rotor

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260

Motorcycle Electric Hub Motor 17×1.6inch 2000 Watt 60KPH Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
4 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
768 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–110 °C
Location and conditions in source details
Suggested cutoff ceiling
110 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW
  • peak: 4 kW

Speed ratings

  • unspecified: 768 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–110 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 30H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 30H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 30H

14 inch 1500 Watt 60V Electric Scooter Moped Wheel Hub Motor

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
3 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
630 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW
  • peak: 3 kW

Speed ratings

  • unspecified: 630 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 60 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 30H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 35H

17 inch 2000W Electric Hub Motor for Motorcycle Application

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 35H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 35H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW · Conflicting sources — do not use
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW · Conflicting sources — do not use

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

Scooter 3000 Watt 13 inch 72V 80KPH Electric Moped Hub Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 48–96 Vmotor

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW · Conflicting sources — do not use
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW · Conflicting sources — do not use

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 70H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
70 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
12 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
28 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW
  • peak: 28 kWfew seconds

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

12 inch Electric Scooter Double Shaft 3000 Watt V1 Hub Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
420 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 420 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 30H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 30H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 30H

Motor Hubs Scooter 14 inch 1500W 72V V1 Detachable BLDC Wheel Hub Motor

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
30 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 30 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 35H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 35H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 35H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
1.5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1.5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 35H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 35H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

Scooter Hub Motor 17inch 3000 Watt V1 72V 70KPH Hub Motor

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

QS260

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

Electric Scooter Hub Motor Wheel 13inch 3000W Hub Motor

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1 40H

QSMOTOR 12×3.5inch 260 2000W V1 Single Shaft Hub Motor

Pole pairs
28
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
120 °C shutdown / 100 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

QS manual recommends 120 C shutdown for its V1 family. Version-family application is separate from exact sensor/installation verification.

QS V1 family manual: shutdown 120 °C; recovery 100 °C. This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1.1 35H

QS Hub Motor 260 12inch 2000W V1.1

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
810 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 810 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 60 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1.1 40H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
950 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • unspecified: 950 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1.1 40H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1.4 50H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v1.4 50H

QS260

Pole pairs
24
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

Electric Moped Hub Mootr 12 inch 3000W V4 Engine for Scooter

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QSMOTOR 12×5.0inch 260 2000W V4 Dual Shaft Hub Motor With Intergrated Design

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
4 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
710 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW
  • peak: 4 kW

Speed ratings

  • unspecified: 710 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
12 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,030 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW
  • peak: 6 kW

Speed ratings

  • unspecified: 1,030 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
840 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • unspecified: 840 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,240 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 10 kW

Speed ratings

  • unspecified: 1,240 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 96 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product category identifies this configuration as Electric Scooter Hub Motor; independently checked against current product page.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

Scooter Electric Hub Motor 12×3.5inch 260 2000W V4 Hub Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
710 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • unspecified: 710 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 48 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4

QS260

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product category identifies this configuration as Electric Scooter Hub Motor; independently checked against current product page.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 48–96 Vmotor

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 35H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
35 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 35 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
2 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 40H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 45H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 50H

5000 Watt 12inch V4 Electric Tricycle Single Shaft Hub Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS260 v4 50H

QS260

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS268 v5 40H

QS268 · 40H; 12-inch hub

Pole pairs
20
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Pole pairs: 20Shared manufacturer 40/50/60 mm option table.Source 1 · Source 2 · Source 3
  • Temperature rating: working temperature range: 70–120 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Temperature rating: peak temperature: 150 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Ingress protection: IP65Shared QS268 V5 40/50/60 mm factory article.Source 1
  • Magnet height: 40 mmSource 1 · Source 2 · Source 3

Configuration notes

  • The factory article identifies all three heights as V5. Power ratings for 40H and 50H are not individually paired with the listed power options.
  • The shared sheet gives 20 pole pairs and dual Hall sets. Temperature sensor, continuous power and peak power are not established for this exact option.
  • Rim width and phase-wire configuration must match the ordered motor; the bundle page contains inconsistent rim-width wording.
  • Shared size-family sheet publishes working temperature 70–120 °C and peak 150 °C; location and duration are unspecified. These are not protection setpoints.
QS Motor

QS268 v5 50H

QS268 · 50H; 12-inch hub

Pole pairs
20
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Pole pairs: 20Shared manufacturer 40/50/60 mm option table.Source 1 · Source 2 · Source 3
  • Temperature rating: working temperature range: 70–120 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Temperature rating: peak temperature: 150 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Ingress protection: IP65Shared QS268 V5 40/50/60 mm factory article.Source 1
  • Magnet height: 50 mmSource 1 · Source 2 · Source 3

Configuration notes

  • The factory article identifies all three heights as V5. Power ratings for 40H and 50H are not individually paired with the listed power options.
  • The shared sheet gives 20 pole pairs and dual Hall sets. Temperature sensor, continuous power and peak power are not established for this exact option.
  • Rim width and phase-wire configuration must match the ordered motor; the bundle page contains inconsistent rim-width wording.
  • Shared size-family sheet publishes working temperature 70–120 °C and peak 150 °C; location and duration are unspecified. These are not protection setpoints.
QS Motor

QS268 v5 60H

QS268 · 60H; 12-inch hub

Pole pairs
20
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
60 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
9 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 9 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Pole pairs: 20Shared manufacturer 40/50/60 mm option table.Source 1 · Source 2 · Source 3 · Source 4
  • Temperature rating: working temperature range: 70–120 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Temperature rating: peak temperature: 150 °CShared 40/50/60 mm manufacturer table; temperature location and duration unspecified. This is not a controller derating or shutdown setting.Source 1
  • Ingress protection: IP65Shared QS268 V5 40/50/60 mm factory article.Source 1
  • Magnet height: 60 mmSource 1 · Source 2 · Source 3 · Source 4

Configuration notes

  • 60H and V5 are explicitly paired with 9 kW on the QS bundle page. No transfer of specifications from the bundled controller.
  • The shared sheet gives 20 pole pairs and dual Hall sets. Temperature sensor, continuous power and peak power are not established for this exact option.
  • Rim width and phase-wire configuration must match the ordered motor; the bundle page contains inconsistent rim-width wording.
  • Shared size-family sheet publishes working temperature 70–120 °C and peak 150 °C; location and duration are unspecified. These are not protection setpoints.
QS Motor

QS268 v5 80H

QS268

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
80 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
20 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,670 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 20 kW
  • peak: 40 kW

Speed ratings

  • unspecified: 1,670 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 80 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS268 v5 90H

V5 Motor QS Hub Motor 25000W 12inch QS Electric Motors for Racing Scooter

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
90 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
25 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
50 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,840 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 25 kW
  • peak: 50 kW

Speed ratings

  • unspecified: 1,840 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • operating Voltage: 48–96 Vmotor

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 90 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,450 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • unspecified: 1,450 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
8 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
890 RPM · no load · motor rotor
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
maximum working temperature: 70 °C
Location and conditions in source details
Suggested cutoff ceiling
70 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • peak: 8 kWReconfirms existing QS273 car 4000W 40H source. Generic QS205 continuous-power discussion lower on page does not apply to this QS273.
  • Manufacturer rated: 4 kW

Speed ratings

  • no load: 890 RPMmotor rotor

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling is capped at 120 C and no higher than the published working limit. This is an inferred protection choice, not a conversion of winding/ambient/peak ratings into a QS cutoff.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: maximum working temperature: 70 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Power: peak: 8 kWReconfirms existing QS273 car 4000W 40H source. Generic QS205 continuous-power discussion lower on page does not apply to this QS273.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 45H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
8 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 8 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
12 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3

Electric Car Hub Motor 72V 6000 Watt V3 Electric Hub Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,200 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW

Speed ratings

  • unspecified: 1,200 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 96 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
3 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 40H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
40 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 40 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 45H

72V 100KPH Electric Scooter 13 inch 6000 Watt V3 Hub Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 45H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 45H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
45 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
6 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 6 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 45 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 50H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
4 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
12 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 4 kW
  • peak: 12 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 50H

16 inch Electric Motorcycle Hub Motor Wheel 273 8000W V3 Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v3 50H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,210 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW

Speed ratings

  • unspecified: 1,210 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • peak Current: 250 Acontroller dc input · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • peak Current: 600 Aphase · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2 · Source 3

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v4

QS273

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
23 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,690 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW
  • peak: 23 kWfew seconds

Speed ratings

  • unspecified: 1,690 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 96 Vmotor
  • continuous Current: 83 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.
  • peak Current: 254 Abattery · Current amplitude convention not specified · Published motor-table value; identify applicable controller, voltage and operating conditions before use.

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v4 50H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v4 50H

Hub Motor for Motorcycle 17 inch 273 8000W V4 Motor

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
50 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
8 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY83-122 · optional
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kW

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 50 mmSource 1

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v4 70H

Motorcycle Hub Motor QS Motor 12000W 17×6.0inch 273 E-Motorcycle Hub Motor

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
70 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
12 kW · Conflicting sources — do not use
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW · Conflicting sources — do not use

Speed ratings

  • Not published

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS273 v4 70H

QS273

Pole pairs
16
Physical rotor unless stated
Magnet construction
Surface magnets · family guidance
Exact model confirmation pending; source details below
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
70 mm magnet height
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
No gearbox
Rated power
12 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
1,400 RPM · unspecified · shaft reference unspecified
Base, no-load and flux-weakening figures retain their labels
Temperature sensor
KTY83-122
Position sensor options
Hall
Operating / winding temperatures
working temperature range: 70–120 °C
Location and conditions in source details
QS protection guidance
145 °C shutdown / 110 °C recovery
Version-family manual; exact installation still needs verification
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kW

Speed ratings

  • unspecified: 1,400 RPMShaft reference not specified · Load/rating basis not stated

Magnet construction evidence

SiAECOSYS identifies wheel-hub motors as surface mount in its controller manual. This is family-level guidance; an exact-model rotor drawing or construction statement has not been established for this entry.

Manufacturer family guidance

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Gearbox evidence

No internal gearbox inferred from the exact in-wheel offering and QS outer-rotor hub construction. The rotor carries the wheel; overall motor-to-wheel ratio is 1. This is not an internal-reduction rating.

Gearbox reference

Temperature protection guidance

Suggested protection ceiling uses the upper end of this model's published working range, capped at 120 C. Peak and insulation temperatures are not used as cutoff settings. This is GDriver guidance, not a QS exact-model protection setting.

QS V2/V3/V4 family manual: shutdown 145 °C; recovery 110 °C; 50% current at 130 °C (30 seconds). This family guidance is separate from the suggested ceiling above.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor

Published specifications and qualifications

  • Temperature rating: working temperature range: 70–120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Temperature rating: peak temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • Drive type: hubExact product description identifies this placement; no topology inferred.Source 1
  • Magnet height: 70 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
QS Motor

QS90 80H

QSD090A-80

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 10–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
80 mm magnet height
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
1 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Operating / winding temperatures
Not published
Suggested cutoff ceiling
120 °C
GDriver suggestion; exact setup not validated; keep any lower working limit
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kW

Speed ratings

  • Not published

Gearbox evidence

No extra gearbox inferred from the exact QS direct shaft-output model family, distinct from the named QSJ geared offerings. Product identity and manufacturer specification are the basis; a plain exterior alone is not proof.

Gearbox reference

Temperature protection guidance

Provisional 120 C ceiling inferred conservatively from the lower QS family shutdown guidance. Exact-model protection/recovery is not established; retain a lower working manufacturer tune and verify the sensor.

Exact-model shutdown and recovery settings have not been established.

Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source · Temperature guidance source

Published specifications and qualifications

  • Drive type: mid-driveExact product description identifies this placement; no topology inferred.Source 1
  • Magnet construction: IPM90 V1 1000W; taper/belt shaft; exact model shown in kit tableSource 1 · Source 2
  • Magnet height: 80 mmSource 1 · Source 2

Configuration notes

  • Missing version is never V1 by default. Verified 138 part-code mappings are scoped: QSD138A70→V1, QSD138B70→V2, QSJ138A70→V3, QSJ138J90 liquid→V3. Other unversioned 138 parts remain explicit. QS165 5-pair QSD165D50 is not established as the same hardware as the 7-pair encoder offering. Hub rim, stator, mounting and winding variants need their own identity review.
ReVolt

RV-100-regular

manufacturer page captured 2026-09-15

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
2 kW
See source conditions below
Peak / maximum power
5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 2 kWVoltage range 24–96 V; cooling, rpm, ambient and power measurement basis not specified.
  • peak: 5 kWDuration and measurement basis unspecified.

Speed ratings

  • Not published

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Published specifications and qualifications

  • Power: continuous: 2 kWVoltage range 24–96 V; cooling, rpm, ambient and power measurement basis not specified.Source 1
  • Power: peak: 5 kWDuration and measurement basis unspecified.Source 1
ReVolt

RV-100Em

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
6 kW
Peak / maximum power
11 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
4,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 6 kW
  • peak: 11 kW

Speed ratings

  • maximum: 4,000 RPMShaft reference not specified · 25°C ambient; recommended maximum, not rated speed

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–96 Vmotor
  • kv: 36–102 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
ReVolt

RV-120Em

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
10 kW
Peak / maximum power
18 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
3,750 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 10 kW
  • peak: 18 kW

Speed ratings

  • maximum: 3,750 RPMShaft reference not specified · 25°C ambient; recommended maximum, not rated speed

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–96 Vmotor
  • kv: 27–63 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
ReVolt

RV-120Esm

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
8 kW
Peak / maximum power
15 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
3,750 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 8 kW
  • peak: 15 kW

Speed ratings

  • maximum: 3,750 RPMShaft reference not specified · 25°C ambient

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–96 Vmotor
  • kv: 30–94 manufacturer-KVShaft reference not specified · Order-dependent winding; KV has no explicit RPM/V unit in the table.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
ReVolt

RV-160-Pro

optional SS411 / S41F Hall sensors fitted

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets
Confirmed from rotor images
FarDriver AN
AN 0
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
9 kW
Peak / maximum power
18 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY-84 · optional
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 120 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 9 kW
  • peak: 18 kW

Speed ratings

  • Not published

Voltage, current and drivetrain

  • operating Voltage: 24–96 Vmotor
  • kv: 20–90 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 120 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: surfaceRV-160-Pro, non-E model: surface magnets are directly visible in a named firsthand 2016 teardown. Current factory page retains the model name and 12N14P geometry. Visual construction evidence is scoped to the photographed RV-160-Pro specimen; it is not a manufacturer certification of all production years. Do not transfer to RV-160Em/Es/Esm, whose factory description identifies a redesigned rotor, or transfer the old specimen power/temperature claims.Source 1 · Source 2 · Source 3
ReVolt

RV-160Em

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
15 kW
Peak / maximum power
28 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
3,500 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 15 kW
  • peak: 28 kW

Speed ratings

  • maximum: 3,500 RPMShaft reference not specified · 25°C ambient; recommended maximum, not rated speed

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–156 Vmotor
  • kv: 19–47 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
ReVolt

RV-160Es

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
12 kW
Peak / maximum power
21 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 12 kW
  • peak: 21 kW

Speed ratings

  • Not published

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–156 Vmotor
  • kv: 28–70 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
ReVolt

RV-160Esm

Pole pairs
7
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
12 kW
Peak / maximum power
21 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
3,500 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
KTY-84
Position sensor options
Hall
Operating / winding temperatures
maximum continuous operating temperature: 150 °C
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 12 kW
  • peak: 21 kW

Speed ratings

  • maximum: 3,500 RPMShaft reference not specified · 25°C ambient; recommended maximum, not rated speed

Construction inference and conditional AN guidance

ReVolt describes an external rotor ring and, for E variants, thicker magnets/rotor and external cooling fins. This is consistent with retaining the surface magnets exposed in the documented non-E RV-160-Pro teardown.

  • Outer-rotor construction alone does not prove surface magnets.
  • The factory explicitly changed the E rotor; continuity of magnet placement is inferred, not certified.
  • The old teardown does not establish the exact model, production year, ratings or limits of this entry.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory family description identifies the external rotor ring and changes to magnet/rotor thickness on E motors. It does not expressly say SPM. · 2016-10-08 firsthand build report identifies RV-160 Pro, shows disassembly and specifies 12N14P. Custom 75 KV winding and cooling modifications are reported. · Personally inspected open rotor image IMG_20160719_125744881_HDR: bare magnet tiles attached to the inside circumference of the rotor shell, directly facing the stator/air gap; no iron pole face covering the magnets. · Exact non-E RV-160-Pro identity cross-check: 165 mm diameter, 122 mm length, 20 mm shaft, 12N14P. Factory 9/18 kW and 120 C specifications remain separate from old owner ratings. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Voltage, current and drivetrain

  • operating Voltage: 24–156 Vmotor
  • kv: 28–70 manufacturer-KVShaft reference not specified · Order-dependent windings; the range does not select a winding.

Published specifications and qualifications

  • Temperature rating: maximum continuous operating temperature: 150 °CPublished limit or rating; not an automatic controller derate or cutoff.Source 1
Sotion

D120L100-3000

72 V; 12 kg; listed under FW09 navigation

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
3 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
3,500 RPM · shaft reference unspecified
Maximum / peak RPM
5,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kWNot continuous-duty qualified
  • peak: 6 kWDuration unspecified

Speed ratings

  • manufacturer rated: 3,500 RPMShaft reference not specified · Exact published configuration: 72 V; 12 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 5,000 RPMShaft reference not specified · Exact published configuration: 72 V; 12 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Gearbox evidence

1:1 rotor-to-output ratio inferred for the original D120L100-3000 configuration on Sotion’s three-column D120 sheet. Its centered shaft, compact end covers and chain-sprocket output match the direct-output D120 package in the paired factory drawing. A same-axis gearbox cannot be ruled out by an exterior drawing alone; this remains an inference, not a published ratio. It does not apply to later D120 versions with a separate reduction housing.

Gearbox reference · Gearbox reference

Published specifications and qualifications

  • Rated power: 3 kWNot continuous-duty qualifiedSource 1
  • Peak power: 6 kWDuration unspecifiedSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • insulation Class Temperature: 155 °CSource 1
  • Ingress protection: IP67Source 1
  • cooling: airSource 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 3,500 RPMExact published configuration: 72 V; 12 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 5,000 RPMExact published configuration: 72 V; 12 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

D120L50-1000

72 V; 5 kg; listed under FW09 navigation

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
1 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
2 kW · peak
Published label; duration and conditions in source details
Rated RPM
3,500 RPM · shaft reference unspecified
Maximum / peak RPM
5,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 1 kWNot continuous-duty qualified
  • peak: 2 kWDuration unspecified

Speed ratings

  • manufacturer rated: 3,500 RPMShaft reference not specified · Exact published configuration: 72 V; 5 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 5,000 RPMShaft reference not specified · Exact published configuration: 72 V; 5 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Gearbox evidence

1:1 rotor-to-output ratio inferred for the original D120L50-1000 configuration on Sotion’s three-column D120 sheet. Its centered shaft, compact end covers and chain-sprocket output match the direct-output D120 package in the paired factory drawing. A same-axis gearbox cannot be ruled out by an exterior drawing alone; this remains an inference, not a published ratio. It does not apply to later D120 versions with a separate reduction housing.

Gearbox reference · Gearbox reference

Published specifications and qualifications

  • Rated power: 1 kWNot continuous-duty qualifiedSource 1
  • Peak power: 2 kWDuration unspecifiedSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • insulation Class Temperature: 155 °CSource 1
  • Ingress protection: IP67Source 1
  • cooling: airSource 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 3,500 RPMExact published configuration: 72 V; 5 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 5,000 RPMExact published configuration: 72 V; 5 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

D120L70-2000

72 V; 8 kg; listed under FW09 navigation

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
2 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
4 kW · peak
Published label; duration and conditions in source details
Rated RPM
3,500 RPM · shaft reference unspecified
Maximum / peak RPM
5,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 2 kWNot continuous-duty qualified
  • peak: 4 kWDuration unspecified

Speed ratings

  • manufacturer rated: 3,500 RPMShaft reference not specified · Exact published configuration: 72 V; 8 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 5,000 RPMShaft reference not specified · Exact published configuration: 72 V; 8 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Gearbox evidence

1:1 rotor-to-output ratio inferred for the original D120L70-2000 configuration on Sotion’s three-column D120 sheet. Its centered shaft, compact end covers and chain-sprocket output match the direct-output D120 package in the paired factory drawing. A same-axis gearbox cannot be ruled out by an exterior drawing alone; this remains an inference, not a published ratio. It does not apply to later D120 versions with a separate reduction housing.

Gearbox reference · Gearbox reference

Published specifications and qualifications

  • Rated power: 2 kWNot continuous-duty qualifiedSource 1
  • Peak power: 4 kWDuration unspecifiedSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • insulation Class Temperature: 155 °CSource 1
  • Ingress protection: IP67Source 1
  • cooling: airSource 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 3,500 RPMExact published configuration: 72 V; 8 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 5,000 RPMExact published configuration: 72 V; 8 kg; listed under FW09 navigation. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

Dragon 01

96 V; 330x410 mm; 54.55 kg; rear hub

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
50 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
100 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,400 RPM · shaft reference unspecified
Maximum / peak RPM
3,500 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 50 kWFactory rated label; continuous duty not specified
  • peak: 100 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,400 RPMShaft reference not specified · Exact published configuration: 96 V; 330x410 mm; 54.55 kg; rear hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 3,500 RPMShaft reference not specified · Exact published configuration: 96 V; 330x410 mm; 54.55 kg; rear hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Rated power: 50 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 100 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 16Source 1
  • cooling: waterSource 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 1,400 RPMExact published configuration: 96 V; 330x410 mm; 54.55 kg; rear hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 3,500 RPMExact published configuration: 96 V; 330x410 mm; 54.55 kg; rear hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

ElectricGen Light Bee Edition

Sotion ElectricGen Edition · Sur-Ron Light Bee custom ElectricGen edition

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
13 kW
See source conditions below
Continuous power
13 kW
See source conditions below
Peak / maximum power
26 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC KTY83 · Unconfirmed
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 13 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.
  • continuous: 13 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.
  • peak: 26 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.

Speed ratings

  • Not published

Published specifications and qualifications

  • Magnet construction: IPMCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Drive type: midCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Continuous power: 13 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Rated power: 13 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Peak power: 26 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Pole pairs: 5Custom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Position sensor: HallCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • temperature Sensor Wording: NTC KTY83 · UnconfirmedCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1

Configuration notes

  • Custom rotor/stator and integrator specifications do not establish equality with stock FW01/FW02.
Sotion

FW01

2 configurations · Encoder or Hall

View configurations and sources
Manufacturer offers Hall and Encoder under the same FW01 product. Temperature-sensor and dimension conflicts in distributor records remain specific to those records.
Sotion

FW01 Encoder

FW01 · 180x145 mm; encoder; NTC

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
13 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
26 kW · peak
Published label; duration and conditions in source details
Rated RPM
5,200 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 13 kWManufacturer rated; continuous duty is not specified
  • peak: 26 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 5,200 RPMShaft reference not specified
  • peak: 9,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • rated Voltage: 72 Vmotor
  • peak Current: 800 Aphase · Current amplitude convention not specified

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 13 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 26 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: ipmStandard FW01 72V 13kW, 180x145 mm. TB Electric explicitly identifies IPM construction on its FW01 listing with Hall and encoder options; the manufacturer lists those options under the same model. This does not transfer custom-edition power or thermal ratings.Source 1 · Source 2
Sotion

FW01 Hall

FW01 · 72V 13kW

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
13 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
26 kW · peak
Published label; duration and conditions in source details
Rated RPM
5,200 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC · Conflicting sources — do not use
PT1000 · Conflicting sources — do not use
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 13 kW
  • peak: 26 kW

Speed ratings

  • manufacturer rated: 5,200 RPMShaft reference not specified · Darwin EV Hall configuration. CMPO MTR023 lists 5900 RPM and different weight/torque; applicability is unresolved.
  • peak: 9,000 RPMShaft reference not specified

Published specifications and qualifications

  • magnet Construction: ipmStandard FW01 72V 13kW, 180x145 mm. TB Electric explicitly identifies IPM construction on its FW01 listing with Hall and encoder options; the manufacturer lists those options under the same model. This does not transfer custom-edition power or thermal ratings.Source 1 · Source 2

Configuration notes

  • Custom rotor/stator and integrator specifications do not establish equality with stock FW01/FW02.
Sotion

FW01 Pro

72V 16kW

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
16 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
32 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,500 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 16 kW
  • peak: 32 kW

Speed ratings

  • manufacturer rated: 6,500 RPMShaft reference not specified
  • peak: 9,000 RPMShaft reference not specified

Published specifications and qualifications

  • magnet Construction: ipmStandard FW01 Pro for Ultra Bee, 72V 16kW/32kW, 180x234 mm. The exact-model authorized dealer listing explicitly identifies IPM construction, corroborated by Darwin EV. Custom MTO edition specifications are not inherited.Source 1 · Source 2
Sotion

FW02

Current manufacturer product-page identity

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • Drive type: midSource 1
  • advertised Power: 12 kWTitle only; rating kind not suppliedSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CSource 1
  • Position sensor: Hall / EncoderManufacturer FW02 product selector offers Hall and Encoder. This confirms model-level ordering options; it does not resolve which sensor is fitted to distributor SKU MTR025.Source 1
  • magnet Construction: ipmStandard FW02 72V 12kW, 180x145 mm. TB Electric explicitly identifies IPM construction for FW02 and offers Hall/encoder versions. This does not transfer GLE custom-edition ratings or resolve the MTR025 sensor-label conflict.Source 1 · Source 2

Configuration notes

  • The manufacturer offers Hall and Encoder under FW02 product ID 9642442096956. MTR025 still has conflicting fitted-sensor claims; the two options do not resolve which one that SKU actually contains.
Sotion

FW02 (MTR025)

FW02 · 72V 12kW MTR025

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
24 kW · peak
Published label; duration and conditions in source details
Rated RPM
5,200 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • nominal: 12 kW
  • peak: 24 kW

Speed ratings

  • manufacturer rated: 5,200 RPMShaft reference not specified
  • peak: 10,000 RPMShaft reference not specified

Published specifications and qualifications

  • magnet Construction: ipmStandard FW02 72V 12kW, 180x145 mm. TB Electric explicitly identifies IPM construction for FW02 and offers Hall/encoder versions. This does not transfer GLE custom-edition ratings or resolve the MTR025 sensor-label conflict.Source 1 · Source 2

Configuration notes

  • The manufacturer offers Hall and Encoder under FW02 product ID 9642442096956. MTR025 still has conflicting fitted-sensor claims; the two options do not resolve which one that SKU actually contains.
  • Custom rotor/stator and integrator specifications do not establish equality with stock FW01/FW02.
Sotion

FW03 Hairpin

FW03 hairpin · 72 V; 180x234 mm; 12 kg; magnetic encoder

Pole pairs
4
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.52:1
Multiply by the external sprocket or belt ratio
Rated power
15 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
30 kW · peak
Published label; duration and conditions in source details
Rated RPM
7,000 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 15 kWManufacturer rated; continuous duty is not specified
  • peak: 30 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 7,000 RPMShaft reference not specified · Exact published configuration: 72 V; 180x234 mm; 12 kg; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 180x234 mm; 12 kg; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Voltage, current and drivetrain

  • internal Reduction: 2.52 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 15 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 30 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 180 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTC10KSource 1
  • Pole pairs: 4Source 1
  • cooling: airSource 1
  • Ingress protection: IP65Source 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 7,000 RPMExact published configuration: 72 V; 180x234 mm; 12 kg; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 180x234 mm; 12 kg; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 2.52 input-revolutions/output-revolutionFW03 hairpin: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW03 hairpin: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW04

72 V; 160x250 mm; magnetic encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.52:1
Multiply by the external sprocket or belt ratio
Rated power
10 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
20 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kWManufacturer rated; continuous duty is not specified
  • peak: 20 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified · Exact published configuration: 72 V; 160x250 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 9,000 RPMShaft reference not specified · Exact published configuration: 72 V; 160x250 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Voltage, current and drivetrain

  • internal Reduction: 2.52 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 10 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 20 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 6,000 RPMExact published configuration: 72 V; 160x250 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 9,000 RPMExact published configuration: 72 V; 160x250 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 2.52 input-revolutions/output-revolutionFW04: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW04: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW06

72 V; 110x170 mm; Hall

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Confirmed from rotor images
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
6 kW · peak
Published label; duration and conditions in source details
Rated RPM
7,000 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3 kWManufacturer rated; continuous duty is not specified
  • peak: 6 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 7,000 RPMShaft reference not specified · Exact published configuration: 72 V; 110x170 mm; Hall. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 9,000 RPMShaft reference not specified · Exact published configuration: 72 V; 110x170 mm; Hall. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 3 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 6 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • magnet Construction: ipmFW06 72V 3kW, 110x170 mm. The seller's named FW06 video and its D90 teardown gallery show the identical serial SOTION110YC7260404NA00001. The removed rotor visibly has buried V-shaped magnets. This is exact-specimen visual evidence, not a manufacturer certification or proof that every D90-labelled motor is identical; no FW11 or other model inherits it.Source 1 · Source 2 · Source 3 · Source 4
  • rated Speed: 7,000 RPMExact published configuration: 72 V; 110x170 mm; Hall. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 9,000 RPMExact published configuration: 72 V; 110x170 mm; Hall. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

FW07

72 V; 200x275 mm; encoder; water cooled

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
Confirmed from rotor images
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
2.52:1
Multiply by the external sprocket or belt ratio
Rated power
15 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
30 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,900 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 15 kWManufacturer rated; continuous duty is not specified
  • peak: 30 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 6,900 RPMShaft reference not specified · Exact published configuration: 72 V; 200x275 mm; encoder; water cooled. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 200x275 mm; encoder; water cooled. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Voltage, current and drivetrain

  • internal Reduction: 2.52 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 15 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 30 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • cooling: waterSource 1
  • Ingress protection: IP67Source 1
  • magnet Construction: ipmFW07 water-cooled 15kW motor: firsthand owner identifies the model and photographs its removed rotor. The exposed outer rotor has continuous iron laminations and shaped iron pole faces rather than surface-mounted magnets, supporting IPM construction. This is visual teardown evidence, not a manufacturer declaration; no dimensions, gear ratio or custom tuning values are transferred.Source 1 · Source 2 · Source 3
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously. Additional option comes from an exact named factory motor/controller kit; retain the separately documented specification-sheet sensor configuration.Source 1 · Source 2
  • rated Speed: 6,900 RPMExact published configuration: 72 V; 200x275 mm; encoder; water cooled. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 200x275 mm; encoder; water cooled. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 2.52 input-revolutions/output-revolutionFW07: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW07: manufacturer specification publishes 2.52:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW10

72 V; 200x240 mm; encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
3.78:1
Multiply by the external sprocket or belt ratio
Rated power
5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
5,500 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kWManufacturer rated; continuous duty is not specified
  • peak: 10 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 5,500 RPMShaft reference not specified · Exact published configuration: 72 V; 200x240 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 200x240 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Construction inference and conditional AN guidance

Likely IPM: the original Sotion 138C/MG138-C 5 kW teardown shows buried V magnets. Its 72 V, five-pole-pair, approximately 3.78:1 geared layout, 84 mm body section and distinctive offset gearbox/housing arrangement correspond closely to the factory FW10. This supports a construction-family inference, not an established model alias.

  • No source explicitly equates MG138-C/M138CL with FW10, and no exact current FW10 rotor teardown was found.
  • The older sheet gives 210x240 mm, 12.5 kg, 5600/9000 RPM, class B and IP65; the FW10 sheet gives 200x240 mm, 11 kg, 5500/10000 RPM, class F and IP67. Mount dimensions and overall drawing length also differ. The shared layout does not establish identical internals.
  • Keep the FW10 factory 3.78:1 value. Do not substitute the legacy 3.7857 ratio, copy legacy temperatures, or treat insulation class as a protection cutoff.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Original seller/owner dewz, post 7 dated 2023-02-27, identifies the opened motor as Sotion 138C 5 kW; post 3 supplies the MG138-C sheet. · Personally inspected end faces show magnet bars inside V-shaped pockets under the rotor iron. The physical observation is of the legacy 138C, not an exact current FW10. · Dealer photos and MG138-C specification/dimension images document the earlier geared family; the page does not name FW10. · Exact FW10 factory listing and attached drawings provide the current model identity. · FW10 sheet: 72 V, 5/10 kW, five pole pairs, 3.78 ratio, PT1000 and encoder. It does not state magnet placement. · Personally compared gearbox outline, case details and 84 mm body section with the MG138-C drawing; mounting dimensions differ.

FarDriver AN guidance

Voltage, current and drivetrain

  • internal Reduction: 3.78 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 5 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 10 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 5,500 RPMExact published configuration: 72 V; 200x240 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 200x240 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 3.78 input-revolutions/output-revolutionFW10: manufacturer specification publishes 3.78:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW10: manufacturer specification publishes 3.78:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW11 v2

FW11 V2 · 72 V; factory sheet FW11V2; 115x165 mm; 5.7 kg

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
5,000 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kWFactory rated label; continuous duty not specified
  • peak: 10 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 5,000 RPMShaft reference not specified · Exact published configuration: 72 V; factory sheet FW11V2; 115x165 mm; 5.7 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; factory sheet FW11V2; 115x165 mm; 5.7 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Construction inference and conditional AN guidance

Likely IPM: the March 2024 FW11 discussion includes a rotor photo with magnets embedded in V-shaped pockets. E-Conic sells FW11 v1 and v2 together and describes the v2 update as extended phase wires and better waterproofing, supporting continuity of the FW11 motor platform. This supports a moderate inference for v2, not confirmation of its exact rotor.

  • The photographed rotor is associated with the earlier FW11 in the post; it has no visible model plate, serial number or v2 identifier.
  • The post predates the November 2025 v2 update. No exact FW11 v2 rotor photo or explicit manufacturer IPM statement was found.
  • The dealer update description supports version lineage but does not explicitly guarantee unchanged rotor construction; unlisted internal revisions remain possible.
  • The post itself uses tentative IPM wording. Its photograph supports the construction inference; its generalized efficiency, magnet-count and simulated 20kW claims are not adopted as specifications.
  • This inference applies only to FW11 v2. It does not establish construction for FW23, GTS11-C or GTS11-D, or controller/sensor compatibility.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Public March 11, 2024 post by Roengchai Kotatha discusses FW11, attaches rotor and stator photographs, and refers to their magnet/copper size in replies. The post names FW11, not FW23 or FW11 v2. · Inspected full-size attached rotor photograph: magnet bars are buried in V-shaped pockets in the laminated rotor, visibly IPM construction. No model plate or exact revision is visible. Downloaded image SHA256 b389049b06bea08517ff78893e98e3a7000b44d78b4b828e53aaccb788a60c91. · Seller offers V1 (Black Wire) and V2 (Long Orange Wire & Includes Reinforcement Bracket) under one FW11 listing. Dated November 27, 2025 update names extended 760mm phase lines and better waterproofing. It does not explicitly state that the rotor is unchanged. · Manufacturer identifies the target as FW11 new version/FW11V2, 72V 5kW/10kW. Existing exact-model specification records 5 pole pairs. These establish the target identity, not its magnet placement.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • advertised Power: 5 kWTitle only; rating kind not suppliedSource 1
  • Drive type: midSource 1
  • Rated power: 5 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 10 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 5,000 RPMExact published configuration: 72 V; factory sheet FW11V2; 115x165 mm; 5.7 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; factory sheet FW11V2; 115x165 mm; 5.7 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1

Configuration notes

  • Current navigation label FW11 points to an explicitly titled FW11V2 product. That is a scoped current-page alias, not proof every historical FW11 is V2. FW11V2 and GTS11 have different published ratings; C V2, C V3 and D remain separately designated.
Sotion

FW15-7000

72 V; 145x230 mm; encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
3.78:1
Multiply by the external sprocket or belt ratio
Rated power
7 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
14 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,200 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 7 kWManufacturer rated; continuous duty is not specified
  • peak: 14 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 6,200 RPMShaft reference not specified · Exact published configuration: 72 V; 145x230 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 145x230 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Voltage, current and drivetrain

  • internal Reduction: 3.78 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 7 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 14 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 6,200 RPMExact published configuration: 72 V; 145x230 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 145x230 mm; encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 3.78 input-revolutions/output-revolutionFW15-7000: manufacturer specification publishes 3.78:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW15-7000: manufacturer specification publishes 3.78:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW16

72 V; 299x266x191 mm; magnetic encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
3.786:1
Multiply by the external sprocket or belt ratio
Rated power
3.5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
5.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,600 RPM · shaft reference unspecified
Maximum / peak RPM
8,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3.5 kWManufacturer rated; continuous duty is not specified
  • peak: 5.5 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 6,600 RPMShaft reference not specified · Exact published configuration: 72 V; 299x266x191 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 8,000 RPMShaft reference not specified · Exact published configuration: 72 V; 299x266x191 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Voltage, current and drivetrain

  • internal Reduction: 3.786 input-revolutions/output-revolutionmotor rotor to output shaft

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 3.5 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 5.5 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 130 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: PT1000Source 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP65Source 1
  • Position sensor: EncoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 6,600 RPMExact published configuration: 72 V; 299x266x191 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 8,000 RPMExact published configuration: 72 V; 299x266x191 mm; magnetic encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • internal Reduction: 3.786 input-revolutions/output-revolutionFW16: manufacturer specification publishes 3.7857:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.Source 1

Configuration notes

  • FW16: manufacturer specification publishes 3.7857:1 internal gear reduction. This is motor rotor to output shaft; external sprockets remain a separate ratio.
Sotion

FW20 100V

FW20 · 100 V; 185x170 mm; 15 kg; distinct from 96 V hairpin and H200 sheets

Pole pairs
4
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
40 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
80 kW · peak
Published label; duration and conditions in source details
Rated RPM
15,000 RPM · shaft reference unspecified
Maximum / peak RPM
20,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 40 kWFactory rated label; continuous duty not specified
  • peak: 80 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 15,000 RPMShaft reference not specified · Exact published configuration: 100 V; 185x170 mm; 15 kg; distinct from 96 V hairpin and H200 sheets. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Current 100 V 40/80 kW factory sheet only; older 100 V 35/80 kW dealer sheets publish different speeds and pole pairs.
  • peak: 20,000 RPMShaft reference not specified · Exact published configuration: 100 V; 185x170 mm; 15 kg; distinct from 96 V hairpin and H200 sheets. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Current 100 V 40/80 kW factory sheet only; older 100 V 35/80 kW dealer sheets publish different speeds and pole pairs.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 40 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 80 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 4Source 1
  • cooling: waterSource 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 15,000 RPMExact published configuration: 100 V; 185x170 mm; 15 kg; distinct from 96 V hairpin and H200 sheets. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Current 100 V 40/80 kW factory sheet only; older 100 V 35/80 kW dealer sheets publish different speeds and pole pairs.Source 1
  • peak Speed: 20,000 RPMExact published configuration: 100 V; 185x170 mm; 15 kg; distinct from 96 V hairpin and H200 sheets. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Current 100 V 40/80 kW factory sheet only; older 100 V 35/80 kW dealer sheets publish different speeds and pole pairs.Source 1

Configuration notes

  • 100 V and 96 V hairpin sources share 185×170 mm dimensions but lack a proven winding/revision crosswalk. H200 is 185×325 mm and 32.3 kg; retain the extended designation.
Sotion

FW20 Hairpin 96V

FW20 hairpin · 96 V; 185x170 mm; 15 kg

Pole pairs
4
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
35 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
70 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,600 RPM · shaft reference unspecified
Maximum / peak RPM
11,500 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 35 kWFactory rated label; continuous duty not specified
  • peak: 70 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 6,600 RPMShaft reference not specified · Exact published configuration: 96 V; 185x170 mm; 15 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 11,500 RPMShaft reference not specified · Exact published configuration: 96 V; 185x170 mm; 15 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 35 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 70 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 4Source 1
  • cooling: waterSource 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously. Additional option comes from an exact named factory motor/controller kit; retain the separately documented specification-sheet sensor configuration.Source 1 · Source 2
  • rated Speed: 6,600 RPMExact published configuration: 96 V; 185x170 mm; 15 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 11,500 RPMExact published configuration: 96 V; 185x170 mm; 15 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1

Configuration notes

  • 100 V and 96 V hairpin sources share 185×170 mm dimensions but lack a proven winding/revision crosswalk. H200 is 185×325 mm and 32.3 kg; retain the extended designation.
Sotion

FW20-H200

96 V; extended 185x325 mm; 32.3 kg

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
35 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
70 kW · peak
Published label; duration and conditions in source details
Rated RPM
4,300 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 35 kWFactory rated label; continuous duty not specified
  • peak: 70 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 4,300 RPMShaft reference not specified · Exact published configuration: 96 V; extended 185x325 mm; 32.3 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 35 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 70 kWFactory peak label; duration and test conditions absentSource 1
  • cooling: waterProduct title; second specification panel unavailableSource 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 4,300 RPMExact published configuration: 96 V; extended 185x325 mm; 32.3 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1

Configuration notes

  • 100 V and 96 V hairpin sources share 185×170 mm dimensions but lack a proven winding/revision crosswalk. H200 is 185×325 mm and 32.3 kg; retain the extended designation.
Sotion

FW22

72 V; 148x190 mm; Hall or encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
12 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
25 kW · peak
Published label; duration and conditions in source details
Rated RPM
7,000 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kWManufacturer rated; continuous duty is not specified
  • peak: 25 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 7,000 RPMShaft reference not specified · Exact published configuration: 72 V; 148x190 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 148x190 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 12 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 25 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 7,000 RPMExact published configuration: 72 V; 148x190 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 148x190 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

FW23

72 V; 130x150 mm; Hall or encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
Surface magnets (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 0
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
8 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
16 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 8 kWManufacturer rated; continuous duty is not specified
  • peak: 16 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified · Exact published configuration: 72 V; 130x150 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 130x150 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Construction inference and conditional AN guidance

Likely surface: Sotion representative Becci Alisa published an explicitly named FW23/R72550 tuning recommendation showing Motor field structure set to surface-mount and 5 pole pairs. The same post identifies the 72V 8kW/16kW FW23. This supports a moderate construction inference, not direct verification of the rotor.

  • The evidence is a supplier-published controller setup, not a rotor cutaway or a manufacturer construction specification. The exact motor revision and sensor configuration are not identified.
  • The screenshot also displays inconsistent motor rated voltage/current fields (220V and -2000A), a gear-ratio value of 70, and 10000RPM labeled rated speed. None is adopted as a motor specification or controller preset.
  • Displayed equal D/Q inductance values are controller settings, not documented measurements; they are not treated as independent construction proof.
  • The R72550 screenshot does not specify FarDriver AN. AN 0 is conditional construction-based starting guidance and requires an explicit choice.
  • Applies only to FW23; no transfer to FW23S, FW11 or other Sotion models, and no controller/sensor compatibility is established.

Conditional FarDriver AN 0 starting guidance based on inferred surface construction, not an exact-model tune or the Sotion R72550 settings. Confirm controller/sensor compatibility separately. Keep a working factory tune.

Public April 15, 2025 post by Becci Alisa (Sotion), captioned Sotion FW23 with sotion R72550 tuning recommendation. Its specification image identifies FW23, 72V, 8kW rated, 16kW peak, 6000RPM rated and 10000RPM maximum. · Inspected attached Motor Parameter screenshot: Motor field structure is surface-mount and number of motor pole pairs is 5. Other displayed voltage/current fields are inconsistent and are not adopted. Downloaded image SHA256 bc173a802359a4eb081b65911d6959add1b3ac208e7db9716101dd973fe7ac06. · Factory listing establishes FW23 identity, 72V 8kW/16kW and Hall or encoder options; it does not explicitly specify magnet placement.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 8 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 16 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 6,000 RPMExact published configuration: 72 V; 130x150 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 130x150 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

FW23S

Current manufacturer catalog identity; incomplete numeric specification

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • advertised Power Pair: 7,000 / 14,000 WTitle says 7 kW/14 kW without labelling the rating kinds; not automatically continuous/peakSource 1
Sotion

FW26

72 V; 164x230 mm; 9.5 kg; factory image 5/11 kW

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
11 kW · peak
Published label; duration and conditions in source details
Rated RPM
3,300 RPM · shaft reference unspecified
Maximum / peak RPM
7,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kWFactory rated label; continuous duty not specified
  • peak: 11 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 3,300 RPMShaft reference not specified · Exact published configuration: 72 V; 164x230 mm; 9.5 kg; factory image 5/11 kW. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 7,000 RPMShaft reference not specified · Exact published configuration: 72 V; 164x230 mm; 9.5 kg; factory image 5/11 kW. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 5 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 11 kWFactory peak label; duration and test conditions absentSource 1
  • rated Speed: 3,300 RPMExact published configuration: 72 V; 164x230 mm; 9.5 kg; factory image 5/11 kW. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 7,000 RPMExact published configuration: 72 V; 164x230 mm; 9.5 kg; factory image 5/11 kW. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1

Configuration notes

  • Different dimensions and masses; X1 title and factory image conflict. Do not infer a rename.
Sotion

FW26X1

72 V; 165x200 mm; 9.65 kg; title and factory image disagree

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
10 kW · Conflicting sources — do not use
See source conditions below
Continuous power
Not published
Peak / maximum power
20 kW · Conflicting sources — do not use · peak
Published label; duration and conditions in source details
Rated RPM
5,000 RPM · shaft reference unspecified
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kW · Conflicting sources — do not useImage explicitly rated 10 kW, title advertises 12 kW/25 kW
  • peak: 20 kW · Conflicting sources — do not useImage explicitly peak 20 kW; title advertises 12 kW/25 kW. No revision crosswalk.

Speed ratings

  • manufacturer rated: 5,000 RPMShaft reference not specified · Exact published configuration: 72 V; 165x200 mm; 9.65 kg; title and factory image disagree. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Applies to the pictured 10/20 kW sheet; listing-title ratings remain in conflict.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 10 kW · Conflicting sources — do not useImage explicitly rated 10 kW, title advertises 12 kW/25 kWSource 1 · Source 2
  • Peak power: 20 kW · Conflicting sources — do not useImage explicitly peak 20 kW; title advertises 12 kW/25 kW. No revision crosswalk.Source 1 · Source 2
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously. The published power conflict is unresolved; the sensor selector does not resolve it.Source 1
  • rated Speed: 5,000 RPMExact published configuration: 72 V; 165x200 mm; 9.65 kg; title and factory image disagree. Shaft reference is not expressly identified; peak speed is not a continuous operating limit. Applies to the pictured 10/20 kW sheet; listing-title ratings remain in conflict.Source 1

Configuration notes

  • Different dimensions and masses; X1 title and factory image conflict. Do not infer a rename.
Sotion

FW30

Current manufacturer catalog identity; incomplete numeric specification

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

FW30-A specification reference

FW30-A manufacturer sheet published by TingTong. The Sotion factory listing offers FW30-A and FW30-B; these values apply only to the A sheet and are not general FW30 setup presets. Class F (155°C) is an insulation classification, not a temperature cutoff.

  • rated Voltage: 72 VFW30-A only; applicability to FW30-B is not established.Source 1
  • Rated power: 15 kWFW30-A only; applicability to FW30-B is not established.Source 1
  • Power: peak: 36 kW for 10 secondsFW30-A only; applicability to FW30-B is not established.Source 1
  • rated Torque: 54 NmFW30-A only; applicability to FW30-B is not established.Source 1
  • peak Torque: duration Seconds: 10 · unit: Nm · value: 185FW30-A only; applicability to FW30-B is not established.Source 1
  • rated Speed: 2,500 RPMFW30-A only; applicability to FW30-B is not established.Source 1
  • peak Speed: 4,000 RPMFW30-A only; applicability to FW30-B is not established.Source 1
  • Pole pairs: 4FW30-A only; applicability to FW30-B is not established.Source 1
  • Temperature sensor: PT1000FW30-A only; applicability to FW30-B is not established.Source 1
  • Position sensor: Magnetic encoderFW30-A only; applicability to FW30-B is not established.Source 1
  • gear Ratio: 1:1; direct driveFW30-A only; applicability to FW30-B is not established.Source 1
  • Insulation class: F (155°C)FW30-A only; applicability to FW30-B is not established.Source 1
  • Ingress protection: IP67FW30-A only; applicability to FW30-B is not established.Source 1
  • cooling: Water coolingFW30-A only; applicability to FW30-B is not established.Source 1
  • dimensions: 245 × 310 mmFW30-A only; applicability to FW30-B is not established.Source 1
  • mass: 33.65 kgFW30-A only; applicability to FW30-B is not established.Source 1
Sotion

FW35

Current manufacturer catalog identity; incomplete numeric specification

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published
Sotion

GLE Talaria v2

Sotion GLE V2 · Talaria MX3/MX4 custom GLE edition

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
20.5 kW
See source conditions below
Peak / maximum power
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 20.5 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.
  • peak: 40 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.

Speed ratings

  • Not published

Published specifications and qualifications

  • Magnet construction: IPMCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Drive type: midCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Continuous power: 20.5 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Peak power: 40 kWCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • Position sensor: Hall / EncoderCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1
  • published Thermal Threshold C: 180 °C · UnconfirmedCustom edition only. Power duty conditions, measurement basis and peak duration are unspecified.Source 1

Configuration notes

  • Custom rotor/stator and integrator specifications do not establish equality with stock FW01/FW02.
Sotion

GTS01

96V 20kW; 180x145 mm

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
20 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
10,000 RPM · shaft reference unspecified
Maximum / peak RPM
14,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 20 kW
  • peak: 40 kW

Speed ratings

  • manufacturer rated: 10,000 RPMShaft reference not specified
  • peak: 14,000 RPMShaft reference not specified

Construction inference and conditional AN guidance

Likely IPM: the 96V 20kW racing model matches the FW01 racing-family description, whose standard FW01 anchor is explicitly identified as IPM. EBMX also enables MTPA in its named GTS01 preset. Together these support a moderate inference; neither establishes the actual magnet placement of every GTS01 revision.

  • No exact GTS01 rotor cutaway or explicit manufacturer IPM statement was found.
  • The dealer calls its motor FW01-Racing rather than GTS01. Matching voltage, power, fitment and body size supports the family relationship but does not establish an exact revision or an interchangeable model alias.
  • The dealer lists 8000/12000 RPM while the current factory GTS01 sheet lists 10000/14000 RPM. Its ratings are not transferred to this record.
  • EBMX preset values are controller configuration, not measured motor data. Enabled MTPA and a small nonzero d/q inductance difference do not alone prove IPM construction.
  • The inspected EBMX preset is for a Hall configuration; its tune, temperatures and compatibility are not transferred to FarDriver or to the encoder configuration.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Factory identifies GTS01 as the racing version and offers Hall and encoder configurations; its specification sheet identifies 96V 20kW and 180x145 mm. It does not state magnet placement. · Dealer describes a 96V 20kW/40kW FW01-Racing motor with the same size as standard FW01 13kW and upgraded magnets, copper and phase wires. This supports a family relationship, not exact revision equality or a direct IPM claim. · Model-specific body text explicitly identifies standard FW01 72V 13kW, 180x145 mm, as Internal Magnet Motor (IPM), with Hall/encoder options. This is the family anchor, not a GTS01 construction confirmation. · Official EBMX app listing identifies the publisher and records GTS01 support in its version history. It does not state IPM construction. · Public archive of EBMX app 2.5.36. Signature-verified APK contains assets/flutter_assets/assets/preset/GTS01Motor.xml with foc_mtpa_mode=1, foc_motor_l approximately 15 uH, foc_motor_ld_lq_diff approximately 0.5 uH, and si_motor_poles=10. The same fields occur in 2.5.25. These are software preset values, not measurements or a FarDriver AN recommendation. XML SHA256: 00614872bc3925158e8d3456dad8ca866e1cde392c5dddf010917f6832a655cb.

FarDriver AN guidance

Voltage, current and drivetrain

  • rated Voltage: 96 Vmotor
  • peak Current: 1,300 Aphase · Current amplitude convention not specified
Sotion

GTS01 Pro

96V 25kW

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
25 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
50 kW · peak
Published label; duration and conditions in source details
Rated RPM
9,500 RPM · shaft reference unspecified
Maximum / peak RPM
13,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 25 kW
  • peak: 50 kW

Speed ratings

  • manufacturer rated: 9,500 RPMShaft reference not specified
  • peak: 13,000 RPMShaft reference not specified

Construction inference and conditional AN guidance

Green Line Engineering's indexed GTS Pro listing explicitly described an IPM rotor. Its current product photograph is marked Sotion Gts01 PRO, matching the factory model branding and housing. This supports likely IPM construction for the GTS01 Pro family, without equating the dealer revision to the factory 96 V configuration.

  • The IPM wording was retrieved from the search-indexed page on 2026-10-01; the current live page and product JSON omit that specification. It is not treated as a fresh manufacturer confirmation.
  • The indexed page mixes V3 in its title with V2 in its body. The photographed serial begins 180YC72, while this catalog configuration is 96 V; exact winding and revision identity are not established.
  • Matching external branding does not prove identical internals. No dealer power, temperature, efficiency, current, speed or pole-number claims are transferred.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Search-indexed seller specification describes an IPM rotor for GTS Pro. Current live text omits it; indexed V2/V3 wording remains unresolved. Snapshot stores the indexed retrieval, not live HTML. · Photograph clearly shows Sotion and Gts01 PRO branding; serial 180YC7267417ENA250600028. External model identity only. · Factory GTS01 Pro 96 V product family; this page does not explicitly specify magnet placement. · Factory photograph shows the same Gts01 PRO branding and housing family; not proof of the dealer winding or rotor revision.

FarDriver AN guidance

Published specifications and qualifications

  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
Sotion

GTS11

72 V; 7 kW; 115x165 mm; Hall or encoder

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM (inferred)
Moderate confidence; exact revision not confirmed
FarDriver AN
AN 8–16
Conditional on inferred construction; opt-in only, keep a working AN
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
7 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
15 kW · peak
Published label; duration and conditions in source details
Rated RPM
8,000 RPM · shaft reference unspecified
Maximum / peak RPM
11,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 7 kWManufacturer rated; continuous duty is not specified
  • peak: 15 kWManufacturer peak; duration and test conditions unspecified

Speed ratings

  • manufacturer rated: 8,000 RPMShaft reference not specified · Exact published configuration: 72 V; 7 kW; 115x165 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 11,000 RPMShaft reference not specified · Exact published configuration: 72 V; 7 kW; 115x165 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Construction inference and conditional AN guidance

The independently measured Lq > Ld supports likely IPM construction for GTS11. This is a physical measurement tied to the model name, rather than an assumption from BLDC or encoder terminology.

  • Saliency can also arise from saturation and does not prove buried magnets.
  • The measured specimen is listed at 7.2 kg; the exact factory revision/winding is not established.
  • The numeric inductance measurements are not copied into the motor specification or used to calculate AN.

Conditional FarDriver construction-based starting guidance, not an exact-model tune. Confirm controller/sensor compatibility separately. Keep a working factory tune; do not overwrite it merely because this range is listed.

Named GTS11 row: measured D-axis inductance 22 uH and Q-axis inductance 30 uH. Ratio 1.36 is consistent with rotor saliency. Measurements were at 1 kHz under appreciable current; exact revision is not identified. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement. · Existing catalog source identifying this model/configuration; not an explicit rotor-construction statement.

FarDriver AN guidance

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 7 kWManufacturer rated; continuous duty is not specifiedSource 1
  • Peak power: 15 kWManufacturer peak; duration and test conditions unspecifiedSource 1
  • insulation Class Temperature: 155 °CInsulation class reference; not protection cutoffSource 1
  • Temperature sensor: NTCSource 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 8,000 RPMExact published configuration: 72 V; 7 kW; 115x165 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 11,000 RPMExact published configuration: 72 V; 7 kW; 115x165 mm; Hall or encoder. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1

Configuration notes

  • Current navigation label FW11 points to an explicitly titled FW11V2 product. That is a scoped current-page alias, not proof every historical FW11 is V2. FW11V2 and GTS11 have different published ratings; C V2, C V3 and D remain separately designated.
Sotion

GTS11-C v2

GTS11-C V2 · 72 V; oil seal; MXR / Dragster fitment

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 10 kW

Speed ratings

  • Not published

Published specifications and qualifications

  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • configuration Fitment: Oil seal; MXR / DragsterSupplier-described configuration; mounting tolerances and vehicle revisions still require checking. This is not a rotor-construction claim.Source 1
  • Pole pairs: 5Source 1
  • Temperature sensor: NTC10KSource 1
  • Rated power: 5 kWSource 1 · Source 2
  • Peak power: 10 kWSource 1 · Source 2

Configuration notes

  • Current navigation label FW11 points to an explicitly titled FW11V2 product. That is a scoped current-page alias, not proof every historical FW11 is V2. FW11V2 and GTS11 have different published ratings; C V2, C V3 and D remain separately designated.
Sotion

GTS11-C v3

GTS11-C V3 · 72 V; 115x140 mm; 4.75 kg; no oil seal; Ebox fitment

Pole pairs
5
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
5 kW
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,500 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Encoder
Hall
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kW
  • peak: 10 kW

Speed ratings

  • manufacturer rated: 6,500 RPMShaft reference not specified · Exact published configuration: 72 V; 115x140 mm; 4.75 kg; Ebox exclusive. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 10,000 RPMShaft reference not specified · Exact published configuration: 72 V; 115x140 mm; 4.75 kg; Ebox exclusive. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 5 kWSource 1
  • Peak power: 10 kWSource 1
  • Temperature sensor: NTC10KSource 1
  • Pole pairs: 5Source 1
  • insulation Class Temperature: 155 °CSource 1
  • cooling: airSource 1
  • Ingress protection: IP67Source 1
  • Position sensor: Encoder / HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 6,500 RPMExact published configuration: 72 V; 115x140 mm; 4.75 kg; Ebox exclusive. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 10,000 RPMExact published configuration: 72 V; 115x140 mm; 4.75 kg; Ebox exclusive. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • configuration Fitment: No oil seal; EboxSupplier-described configuration; mounting tolerances and vehicle revisions still require checking. This is not a rotor-construction claim.Source 1

Configuration notes

  • Current navigation label FW11 points to an explicitly titled FW11V2 product. That is a scoped current-page alias, not proof every historical FW11 is V2. FW11V2 and GTS11 have different published ratings; C V2, C V3 and D remain separately designated.
Sotion

GTS11-D

72 V; 115x165 mm; 4.45 kg; Crazy Cart application

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
3.5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
7 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,500 RPM · shaft reference unspecified
Maximum / peak RPM
9,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 3.5 kWFactory rated label; continuous duty not specified
  • peak: 7 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 6,500 RPMShaft reference not specified · Exact published configuration: 72 V; 115x165 mm; 4.45 kg; Crazy Cart application. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 9,000 RPMShaft reference not specified · Exact published configuration: 72 V; 115x165 mm; 4.45 kg; Crazy Cart application. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

Published specifications and qualifications

  • Drive type: midSource 1
  • Rated power: 3.5 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 7 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTC10KSupplier specifies NTC10K; factory sheet identifies NTC. Beta value and controller conversion curve are not published.Source 1 · Source 2
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 5Source 1
  • cooling: airSource 1
  • Position sensor: Hall or encoderPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2 · Source 3
  • rated Speed: 6,500 RPMExact published configuration: 72 V; 115x165 mm; 4.45 kg; Crazy Cart application. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 9,000 RPMExact published configuration: 72 V; 115x165 mm; 4.45 kg; Crazy Cart application. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • magnet Construction: ipmGTS11-D 72V 3.5 kW rated / 7 kW peak Crazy Cart configuration. The supplier explicitly identifies IPM construction in the named model announcement; the factory specification sheet corroborates the exact model and ratings. This is a published supplier specification, not an independent rotor inspection or certification. Other GTS11 variants do not inherit it.Source 1 · Source 2

Configuration notes

  • Current navigation label FW11 points to an explicitly titled FW11V2 product. That is a scoped current-page alias, not proof every historical FW11 is V2. FW11V2 and GTS11 have different published ratings; C V2, C V3 and D remain separately designated.
Sotion

H06

Manufacturer hub listing; no model-specific numeric sheet found

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

Sotion

H10

72 V; H10 rear hub / Razor plug-and-play sheet; 11.6 kg

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,500 RPM · shaft reference unspecified
Maximum / peak RPM
2,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kWFactory rated label; continuous duty not specified
  • peak: 10 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,500 RPMShaft reference not specified · Exact published configuration: 72 V; H10 rear hub / Razor plug-and-play sheet; 11.6 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 2,000 RPMShaft reference not specified · Exact published configuration: 72 V; H10 rear hub / Razor plug-and-play sheet; 11.6 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Drive type: hubSource 1
  • Rated power: 5 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 10 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 16Source 1
  • cooling: airSource 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 1,500 RPMExact published configuration: 72 V; H10 rear hub / Razor plug-and-play sheet; 11.6 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 2,000 RPMExact published configuration: 72 V; H10 rear hub / Razor plug-and-play sheet; 11.6 kg. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

H12W

72 V; 23.4 kg; water-cooled hub

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
12 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
24 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,500 RPM · shaft reference unspecified
Maximum / peak RPM
2,500 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 12 kWFactory rated label; continuous duty not specified
  • peak: 24 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,500 RPMShaft reference not specified · Exact published configuration: 72 V; 23.4 kg; water-cooled hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 2,500 RPMShaft reference not specified · Exact published configuration: 72 V; 23.4 kg; water-cooled hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Rated power: 12 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 24 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 16Source 1
  • cooling: waterSource 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 1,500 RPMExact published configuration: 72 V; 23.4 kg; water-cooled hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 2,500 RPMExact published configuration: 72 V; 23.4 kg; water-cooled hub. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

H16

72 V; 20 kg; 16-inch rear hub; Class B

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
10 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
20 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,200 RPM · shaft reference unspecified
Maximum / peak RPM
1,500 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 10 kWFactory rated label; continuous duty not specified
  • peak: 20 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,200 RPMShaft reference not specified · Exact published configuration: 72 V; 20 kg; 16-inch rear hub; Class B. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 1,500 RPMShaft reference not specified · Exact published configuration: 72 V; 20 kg; 16-inch rear hub; Class B. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Rated power: 10 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 20 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTCSource 1
  • Ingress protection: IP67Source 1
  • Pole pairs: 16Source 1
  • cooling: airSource 1
  • Insulation class: BNo numeric thermal cutoff inferredSource 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 1,200 RPMExact published configuration: 72 V; 20 kg; 16-inch rear hub; Class B. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 1,500 RPMExact published configuration: 72 V; 20 kg; 16-inch rear hub; Class B. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

HB01

72 V; 11 kg; rear hub; 150/175/190 mm dropout options

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
5 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
10 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,100 RPM · shaft reference unspecified
Maximum / peak RPM
1,500 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 5 kWFactory rated label; continuous duty not specified
  • peak: 10 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,100 RPMShaft reference not specified · Exact published configuration: 72 V; 11 kg; rear hub; 150/175/190 mm dropout options. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 1,500 RPMShaft reference not specified · Exact published configuration: 72 V; 11 kg; rear hub; 150/175/190 mm dropout options. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Rated power: 5 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 10 kWFactory peak label; duration and test conditions absentSource 1
  • Temperature sensor: NTC10KSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • cooling: airSource 1
  • Pole pairs: 16Source 1
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1
  • rated Speed: 1,100 RPMExact published configuration: 72 V; 11 kg; rear hub; 150/175/190 mm dropout options. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 1,500 RPMExact published configuration: 72 V; 11 kg; rear hub; 150/175/190 mm dropout options. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Sotion

SHR01

96 V; 330x310 mm; 30 kg; rear hub; sensor unresolved

Pole pairs
16
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
AN 0
General hub starting guidance; confirm your motor setup
Drive type
Direct-drive hub
Magnet / stator size
Not published
Gear ratio
1:1
Direct-drive hub: motor rotor to wheel
Extra gear reduction
Not published
Rated power
40 kW
See source conditions below
Continuous power
Not published
Peak / maximum power
80 kW · peak
Published label; duration and conditions in source details
Rated RPM
1,900 RPM · shaft reference unspecified
Maximum / peak RPM
3,000 RPM · peak · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
other Factory Page: PTC1000 · racing Page: NTC · Conflicting sources — do not use
Position sensor options
Hall
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 40 kWFactory rated label; continuous duty not specified
  • peak: 80 kWFactory peak label; duration and test conditions absent

Speed ratings

  • manufacturer rated: 1,900 RPMShaft reference not specified · Exact published configuration: 96 V; 330x310 mm; 30 kg; rear hub; sensor unresolved. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.
  • peak: 3,000 RPMShaft reference not specified · Exact published configuration: 96 V; 330x310 mm; 30 kg; rear hub; sensor unresolved. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.

FarDriver AN guidance

FarDriver general hub-motor starting guidance: AN 0. This does not establish exact-model rotor construction or a validated motor/controller tune. Confirm the fitted motor and retain a working manufacturer tune when applicable.

Controller manufacturer guidance

Published specifications and qualifications

  • Drive type: hubSource 1
  • Rated power: 40 kWFactory rated label; continuous duty not specifiedSource 1
  • Peak power: 80 kWFactory peak label; duration and test conditions absentSource 1
  • insulation Class Temperature: 155 °CInsulation class reference, not a protection thresholdSource 1
  • Ingress protection: IP67Source 1
  • cooling: waterSource 1
  • Pole pairs: 16Source 1
  • Temperature sensor: other Factory Page: PTC1000 · racing Page: NTC · Conflicting sources — do not useSame named motor and dimensions; no revision identifier explains the sensor difference. PTC1000 preserved as printed, not normalized to PT1000.Source 1 · Source 2
  • Position sensor: HallPublished position-sensor configurations/options for this named motor. This does not establish magnet placement, sensor interchangeability, encoder protocol/resolution, or that both sensor types are fitted simultaneously.Source 1 · Source 2
  • rated Speed: 1,900 RPMExact published configuration: 96 V; 330x310 mm; 30 kg; rear hub; sensor unresolved. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
  • peak Speed: 3,000 RPMExact published configuration: 96 V; 330x310 mm; 30 kg; rear hub; sensor unresolved. Shaft reference is not expressly identified; peak speed is not a continuous operating limit.Source 1
Torp Motors

TM25

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
13 kW
Peak / maximum power
27 kW · peak
31 kW · peak
40 kW · peak
Published label; duration and conditions in source details
Rated RPM
6,000 RPM · shaft reference unspecified
Maximum / peak RPM
10,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 13 kW
  • peak: 27 kW72 V
  • peak: 31 kW80 V
  • peak: 40 kW120 V

Speed ratings

  • manufacturer rated: 6,000 RPMShaft reference not specified
  • maximum: 10,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • operating Voltage: 48–120 Vmotor
  • maximum Current: 800 Aphase · Current amplitude convention not specified
  • kv: 85 RPM/VShaft reference not specified

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Temperature rating: maximum magnet temperature: 150 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Continuous power: 13 kWSource 1
  • Peak power: : 27 kW / : 31 kW / : 40 kW WSource 1
  • Magnet construction: IPMSource 1
  • Drive type: midSource 1
  • Maximum magnet temperature: 150 °CSource 1
  • Temperature sensor: PT1000Source 1
Torp Motors

TM40 PRO

PRO

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
65 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
19 kW
Peak / maximum power
50 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
11,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Hall
Encoder
Choose the fitted configuration; specifications may differ
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 19 kW
  • peak: 50 kW

Speed ratings

  • maximum: 11,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • maximum Current: 1,100 Aphase · Current amplitude convention not specified
  • kv: 97 RPM/VShaft reference not specified

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Temperature rating: maximum magnet temperature: 150 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Continuous power: 19 kWSource 1
  • Peak power: 50 kWSource 1
  • Magnet construction: IPMSource 1
  • Drive type: midSource 1
  • Maximum magnet temperature: 150 °CSource 1
  • Temperature sensor: PT1000Source 1
  • Magnet length: 65 mmSource 1
Torp Motors

TM50 PRO

PRO

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
80 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
24 kW
Peak / maximum power
58 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
11,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 24 kW
  • peak: 58 kW

Speed ratings

  • maximum: 11,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • maximum Current: 1,200 Aphase · Current amplitude convention not specified
  • kv: 88 RPM/VShaft reference not specified · Manufacturer spells RPM as RMP.

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Temperature rating: maximum magnet temperature: 150 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Continuous power: 24 kWSource 1
  • Peak power: 58 kWSource 1
  • Magnet construction: IPMSource 1
  • Drive type: midSource 1
  • Maximum magnet temperature: 150 °CSource 1
  • Temperature sensor: PT1000Source 1
  • Magnet length: 80 mmSource 1
Torp Motors

TM50 SPEED

SPEED

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Mid-drive
Magnet / stator size
80 mm magnet length
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
24 kW
Peak / maximum power
55 kW · peak
Published label; duration and conditions in source details
Rated RPM
13,000 RPM · shaft reference unspecified
Maximum / peak RPM
13,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
PT1000
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • continuous: 24 kW
  • peak: 55 kW

Speed ratings

  • manufacturer rated: 13,000 RPMShaft reference not specified
  • maximum: 13,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • maximum Current: 1,200 Aphase · Current amplitude convention not specified
  • kv: 97 RPM/VShaft reference not specified

Published specifications and qualifications

  • Magnet construction: IPMSource 1
  • Drive type: mid-driveSource 1
  • Temperature rating: maximum magnet temperature: 150 °C (magnets)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • Continuous power: 24 kWSource 1
  • Peak power: 55 kWSource 1
  • Magnet construction: IPMSource 1
  • Drive type: midSource 1
  • Maximum magnet temperature: 150 °CSource 1
  • Temperature sensor: PT1000Source 1
  • Magnet length: 80 mmSource 1
UNITEReference only

MY1020

Brushed PMDC; 350 W; voltage options [24, 36]

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
350 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 350 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Rated power: 350 WSource 1
  • voltage Options: 24 / 36 VSource 1
  • rated Speed: 2,250 RPMSource 1
  • motor Technology: brushed permanent-magnet DCSource 1
  • Magnet construction: Not published · UnconfirmedSPM/IPM brushless permanent-magnet rotor classification does not describe this brushed PMDC architectureSource 1

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
UNITEReference only

MY1020

Brushed PMDC; 500 W; voltage options [24, 36, 48]

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
500 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 500 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Rated power: 500 WSource 1
  • voltage Options: 24 / 36 / 48 VSource 1
  • rated Speed: 2,500 RPMSource 1
  • motor Technology: brushed permanent-magnet DCSource 1
  • Magnet construction: Not published · UnconfirmedSPM/IPM brushless permanent-magnet rotor classification does not describe this brushed PMDC architectureSource 1

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
UNITEReference only

MY1020

Brushed PMDC; 750 W; voltage options [36, 48, 60]

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
750 W
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Manufacturer rated: 750 W

Speed ratings

  • Not published

Published specifications and qualifications

  • Rated power: 750 WSource 1
  • voltage Options: 36 / 48 / 60 VSource 1
  • rated Speed: 2,800 RPMSource 1
  • motor Technology: brushed permanent-magnet DCSource 1
  • Magnet construction: Not published · UnconfirmedSPM/IPM brushless permanent-magnet rotor classification does not describe this brushed PMDC architectureSource 1

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
Ventus / VTB

Beast 28

2 source records · Encoder

View configurations and sources
Both URLs resolve to canonical /products/ URL and Shopify product ID 10199923130652. They are two captures of one US product listing. This does not prove equivalence with the separate BST28 V1.0 datasheet; preserve historical claims.
Ventus / VTB

Beast 28

US Ventus listing; 75 KV; 9500 RPM; 28 kW; V9600 pairing

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
28 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
NTC10K
Position sensor options
Not published
Operating / winding temperatures
Not published
Protection thresholds
Protection derating: 130 °C
Protection shutdown: 150 °C
Specifications, conditions and sources

Power ratings

  • peak: 28 kW

Speed ratings

  • Not published

Published specifications and qualifications

  • Peak power: 28 kWSource 1
  • Magnet construction: IPMSource 1
  • Protection derating: 130 °CBrand US product listing; advertised V9600 system pairing. Not proof of any installed controller settings.Source 1
  • Protection shutdown: 150 °CSame exact source-defined configuration; do not transfer to BST28 V1.0 or RGASource 1
  • Temperature sensor: NTC10KSource 1
  • Pole pairs: 5Source 1

Configuration notes

  • US evidence says 75 KV / 9500 RPM; V1.0 sheet says 77.7 KV / 9000 RPM. Do not map unversioned US listing to V1.0 solely from the Beast/BST name.
Ventus / VTB

Beast 28

BST28 · round-wire Beast 28kW

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
28 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
9,500 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC10K B3905
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 28 kW

Speed ratings

  • maximum: 9,500 RPMShaft reference not specified

Published specifications and qualifications

  • magnet Construction: ipmBeast 28 kW motor as specified by Ventus Bikes USA; not transferred to different Beast document revisions or Ryuga motors.Source 1

Configuration notes

  • US evidence says 75 KV / 9500 RPM; V1.0 sheet says 77.7 KV / 9000 RPM. Do not map unversioned US listing to V1.0 solely from the Beast/BST name.
Ventus / VTB

BST28 77.7KV

BST28 · round wire; 180 × 170 mm

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
28 kW · peak
33 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
9,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC 10k B3905
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 28 kW72 V; natural air cooling
  • peak: 33 kW96 V; natural air cooling

Speed ratings

  • maximum: 9,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • kv: 77.7 manufacturer-KVShaft reference not specified · The table gives KV without an explicit unit; no RPM is derived.

Published specifications and qualifications

  • Temperature rating: insulation rating: 155 °C (insulation)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: ipmBST28 V1.0: JW Shop explicitly describes this named Beast configuration as IPM; the model, KV, dimensions, voltage-specific peak power and RPM match the original Ventus V1.0 PDF. Dealer-published construction claim, not manufacturer certification or an independent teardown. No IPM claim is transferred to Ryuga models or other revisions.Source 1 · Source 2

Configuration notes

  • US evidence says 75 KV / 9500 RPM; V1.0 sheet says 77.7 KV / 9000 RPM. Do not map unversioned US listing to V1.0 solely from the Beast/BST name.
Ventus / VTB

BST48 v1.0

BST48 · round wire; 180 × 196.3 mm

Pole pairs
5
Physical rotor unless stated
Magnet construction
IPM
FarDriver AN
AN 8–16
Starting recommendation; retain a working manufacturer tune
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
37.8 kW · peak
48 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
10,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC 10k B3905
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 37.8 kW72 V; natural air cooling
  • peak: 48 kW96 V; natural air cooling

Speed ratings

  • maximum: 10,000 RPMShaft reference not specified

Voltage, current and drivetrain

  • kv: 91.6 manufacturer-KVShaft reference not specified · The table gives KV without an explicit unit; no RPM is derived.

Published specifications and qualifications

  • Temperature rating: insulation rating: 155 °C (insulation)Published limit or rating; not an automatic controller derate or cutoff.Source 1
  • magnet Construction: ipmBST48 V1.0: JW Shop explicitly describes this named Beast configuration as IPM; the model, KV, dimensions, voltage-specific peak power and RPM match the original Ventus V1.0 PDF. Dealer-published construction claim, not manufacturer certification or an independent teardown. No IPM claim is transferred to Ryuga models or other revisions.Source 1 · Source 2
Ventus / VTB

RGA52 v1.0

RGA52 · hairpin; 173 × 154.9 mm

Pole pairs
4
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
38.4 kW · peak
52.5 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
14,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC 10k B3905
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 38.4 kW72 V; natural air cooling
  • peak: 52.5 kW96 V; natural air cooling

Speed ratings

  • maximum: 14,000 RPMShaft reference not specified

Gearbox evidence

1:1 rotor-to-output ratio inferred for RGA52 V1.0 from the original manufacturer’s motor drawing and direct shaft/pulley package for the bike’s external drivetrain. No integral reduction housing is depicted. The drawing is not an internal cutaway and the sheet does not explicitly state a ratio; verify a modified or differently packaged unit. External belt/chain reduction is separate.

Gearbox reference

Voltage, current and drivetrain

  • kv: 83.3 manufacturer-KVShaft reference not specified · The table gives KV without an explicit unit; no RPM is derived.

Published specifications and qualifications

  • Temperature rating: insulation rating: 250 °C (insulation)Published limit or rating; not an automatic controller derate or cutoff.Source 1
Ventus / VTB

RGA81 v1.0

RGA81 · hairpin; 173 × 180.8 mm

Pole pairs
4
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Mid-drive
Magnet / stator size
Not published
Extra gear reduction
No gearbox
Overall gear ratio still depends on the sprockets or pulleys
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
60.3 kW · peak
81 kW · peak
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
14,000 RPM · maximum · shaft reference unspecified
Published speed rating; conditions below
Other published RPM
Not published
Temperature sensor
NTC 10k B3905
Position sensor options
Encoder
Operating / winding temperatures
Not published
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • peak: 60.3 kW72 V; natural air cooling
  • peak: 81 kW96 V; natural air cooling

Speed ratings

  • maximum: 14,000 RPMShaft reference not specified

Gearbox evidence

1:1 rotor-to-output ratio inferred for RGA81 V1.0 from the original manufacturer’s motor drawing and direct shaft/pulley package for the bike’s external drivetrain. No integral reduction housing is depicted. The drawing is not an internal cutaway and the sheet does not explicitly state a ratio; verify a modified or differently packaged unit. External belt/chain reduction is separate.

Gearbox reference

Voltage, current and drivetrain

  • kv: 118 manufacturer-KVShaft reference not specified · The table gives KV without an explicit unit; no RPM is derived.

Published specifications and qualifications

  • Temperature rating: insulation rating: 250 °C (insulation)Published limit or rating; not an automatic controller derate or cutoff.Source 1

RGA81 / AETOS Max laboratory test (2026-01-27) specification reference

RGA81 with V9600 GEN2 AETOS Max on the VTB laboratory bench, 2026-01-27; forced blower cooling, 96 V supply and field weakening disabled. This is a reported test configuration, not a normal operating recommendation or a FarDriver preset. Exact equivalence to the catalog V1.0 motor revision is not established. Report issued 2026-02-25, V1.0. Its conclusion explicitly excludes prolonged operation at these test temperatures from normal lifetime recommendations.

  • laboratory Motor Derating Setting: 150 °CRGA81 with V9600 GEN2 AETOS Max on the VTB laboratory bench, 2026-01-27; forced blower cooling, 96 V supply and field weakening disabled. This is a reported test configuration, not a normal operating recommendation or a FarDriver preset. Exact equivalence to the catalog V1.0 motor revision is not established. The report explicitly sets motor power reduction to 150 C. This is not a maximum operating temperature or shutdown recommendation.Source 1
  • laboratory Cooling: Fixed-position blower on motor and controllerRGA81 with V9600 GEN2 AETOS Max on the VTB laboratory bench, 2026-01-27; forced blower cooling, 96 V supply and field weakening disabled. This is a reported test configuration, not a normal operating recommendation or a FarDriver preset. Exact equivalence to the catalog V1.0 motor revision is not established. Cooling conditions are part of the reported result.Source 1
  • laboratory Reported Power Timeline: 35 kW for 7 minutes; reduction over 11 minutes; approximately 18 kW for the final 7 minutes of a 25-minute testRGA81 with V9600 GEN2 AETOS Max on the VTB laboratory bench, 2026-01-27; forced blower cooling, 96 V supply and field weakening disabled. This is a reported test configuration, not a normal operating recommendation or a FarDriver preset. Exact equivalence to the catalog V1.0 motor revision is not established. Power measurement point is not established as bare-motor shaft output. The report has inconsistent temperature-column labels between its summary and appendix; these observations are not promoted to continuous-power or thermal-limit presets.Source 1
VEVOR

MY1020

72 V; 3000 W; SKU 010187167720

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
operator: < · value: 120
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • output Power: 3 kWOutput power; no explicit continuous dutySource 1
  • maximum Speed: 5,800 RPMSource 1
  • operating Temperature Upper Bound: operator: < · value: 120Working temperature statement; sensing location unspecified; not a protection thresholdSource 1

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.
VEVOR

MY1020D

72 V; 3000 W; SKU 010307620598

Pole pairs
Not published
Physical rotor unless stated
Magnet construction
Not published
FarDriver AN
Not published
Drive type
Not published
Magnet / stator size
Not published
Extra gear reduction
Not published
Rated power
Not published
Manufacturer-rated; duty not assumed
Continuous power
Not published
Peak / maximum power
Not published
Published label; duration and conditions in source details
Rated RPM
Not published
Maximum / peak RPM
Not published
Other published RPM
Not published
Temperature sensor
Not published
Position sensor options
Not published
Operating / winding temperatures
operator: < · value: 120
Location and conditions in source details
Protection thresholds
Not published
Specifications, conditions and sources

Power ratings

  • Not published

Speed ratings

  • Not published

Published specifications and qualifications

  • output Power: 3 kWOutput power; no explicit continuous dutySource 1
  • maximum Speed: 6,500 RPMSource 1
  • operating Temperature Upper Bound: operator: < · value: 120Working temperature statement; sensing location unspecified; not a protection thresholdSource 1

Configuration notes

  • UNITE entries are brushed PMDC; Kunray entries are BLDC. MY1020 and MY1020D 72 V 3 kW pages publish 4900 versus 6700 RPM. MY1020-WG is a sensor-equipped ordering family. Lunyee publishes BM1109/MY1020D together, but this is not a cross-brand alias certificate.